Specifications
Y1-03-0232G  7 
SECTION 5 - URC-300 MASTER CONTROLLER 
Mounting 
The  Master  Controller  can  be  mounted  in  any  position  near  the 
searchlight  that is  protected from  the weather.  Check  in  advance that 
the  coax  cable  from  the  Point  Pad  and  the wiring  harness  from  the 
searchlight can be routed to this location. Mount the Master Controller 
with the  wires  and coax  facing  down.  Use  an appropriate  fastener  for 
your mounting location.  Use  a sealant  in  fastener  holes  to prevent 
moisture intrusion. 
General wiring scheme 
WARNING:  The RCL-300 has a  unique  wiring scheme. Special 
attention must be paid to the following chart. 
The Master Controller is supplied with an in-line fuse-holder  on the 
Orange  power  lead.  Use  only  30  amp  fuses  in  this  fuse-holder.  See 
chart below for the Master Controller wiring diagram. 
WARNING:  Failure  to  follow  this  arrangement  may  damage 
components. 
Table 1 
  WARNING: This wire MUST be fused with a 30 amp fuse in the 
Master Controller's in-line fuse-holder. 
Master 
Controller 
Wire 
Searchlight  
Cable Wire 
Wire Gauge 
(AWG) 
Power Source 
Lead 
Function 
Orange 
16 
+12 VDC or 
+24 VDC** 
URC-300 Power 
Blue 
16 
Ground 
URC-300 
Ground 
Yellow 
Yellow 
16 
Position Sensor 
Signal 
Green 
Green 
16 
Position Sensor 
Common 
Red 
Red 
16 
Up 
White 
White 
16 
Down 
Black 
Black 
16 
Right 
Brown 
Brown 
16 
Left 
White 
White 
12 
Lamp Power 
Black 
Black 
12 
Lamp Ground 