Operator`s manual
STORAGE
The  RED-D-ARC  MX350  may  be  set  on  a  floor,  or
shelf, horizontally on its skid, or vertically standing on
i
ts rear top and bottom handles.
PROTECTION FEATURES
The  RED-D-ARC  MX350  design  features  electronic
protection  systems  to  help  assure  reliable  operation
even  under  adverse  conditions.  These  systems
include:
FAN AS NEEDED (F.A.N.)
The  cooling  fan  will  turn  on  when  the  arc  starts  and
remain  on  for  about  a  minute  after  the  arc  is  out  to
cool down the power components.
This  feature  electronically  controls  the  fan  so  it  does
not run continuously when the power switch is turned
on. This will minimize the amount of contaminate and
clogging  debris  which  may  be  drawn  into  the
Converter,  in  addition  to  the  "Central-Air"  system
design  which  intakes  lower  velocity  air  through  the
higher  side  louvers  and  blows  out  through  the  lower
back louvers with higher velocity.
OVER-VOLTAGE PROTECTION
Average Input Voltage Protection
The  RED-D-ARC  MX350  input  contactor  will  open  if
the  average  input  supply  voltage  is  above  113VDC,
and will automatically reclose if the voltage drops back
below.  During  Over-Voltage  Shutdown  the  panel  dis-
plays will be as appropriate for the non-welding mode.
(See FRONT PANEL CONTROLS in this section).
When the contactor  recloses  the  output  of  the
Converter will  reactivate. Switching  OFF  input
power prevents unexpected reactivation.
------------------------------------------------------------------------
Peak Input Voltage Protection
The Chopper PC Board  will  stop  switching  and  inter-
rupt  the  machine  output  whenever  the  input  voltage
across the input capacitors exceeds their 150 volt rat-
ing. The Thermal Shutdown (yellow) panel light will be
lit  when  this  protection  is  activated  (Refer  to  OVER-
TEMPERATURE  SHUTDOWN  Section),  and  resets
when  the  voltage  level  drops  below  the  protection
level. The input contactor also opens during this shut
down, until reset.
This  feature  protects  internal  components  of  the
Converter from excessive voltage levels.
CAUTION
B-3
OPERATION
B-3
PARALLELED CONVERTERS
RED-D-ARC MX350 converters that are paralleled (see
INTER-CONNECTION  OF  CONVERTERS  in  the
I
NSTALLATION  section)  must  each  be  set  up  in  the
same manner in order to manage the arc current drawn
f
rom each:
 1) Set  to  CC  mode  with  CC  SLOPE  switch  set  to
STICK/GOUGE.
 2) Preset Output Controls of both paralleled
Converters to ~1/2 desired total Amps.
If  arc  current  from  each  Converter  gets  too  out  of  bal-
ance (primarily a problem if trying to use CV mode) the
hotter  running  Converter  could  go  into  current-limiting
and/or Thermal shutdown (See OVER-TEMPERATURE
SHUTDOWN  in  the  INSTALLATION  section),  which
might  then  overload  the  other,  or  at  least  interrupt  the
operator’s  process.  However,  no  damage  will  occur  to
the Converters.
REMOTE CONTROL OF
PARALLELED CONVERTERS
(FOR CC STICK/GOUGE MODE ONLY)
Full Range remote control can  be accomplished with a
separate  optional  Remote  output  control (see  INSTAL-
LATION section) connected to each Converter. The cur-
rent  contribution  of  each  Converter  will  depend  on  its
remote output setting.
Partial Range remote control can be accomplished with
a  single  Remote  Control  connected  to  the  output
Converter with the input Converter preset with its panel
Output  Control  to  below  the  minimum  desired  output
range.  The  Remote  Control,  connected  to  the  output
Converter,  will  control  its  output  to  add  to  the  preset
level.
TRANSPORTING AND  STORAGE  OF
THE RED-D-ARC MX350
CABLE HANDLING
The input and electrode cables are easily disconnected
from  the    quick-connect  "pig-tails",  and  the  Work  lead
can be reeled around the RED-D-ARC MX350 case cra-
dled by the base skid handles, to which the clip can be
secured.
TRANSPORTING
The  Converter  may  be  carried  by  one  or  two  persons
using the front and rear top and bottom handles. It can
also be set vertically on a two wheel cart, or horizontally
RED-D-ARC MX350










