User guide
10
OM Commands
(NTP 297-1001-300, Basic Administration Procedures)
Note: The following OM commands are used to add, delete, change, dis-
play, and query OM data:
>CLRINVREG Can be used to clear invalid INWATS registers
after a restart. Use it before reading or resetting
INWATS registers after a restart.
>
OMSHOW
Displays all or part of a specified OM group's key
structure and part or all of the contents.
i.e. >OMSHOW UTR HOLDING
>
Q OMSHOW
Use this command to get a list of the OM groups
and classes defined by the OMCLASS command.
>OMDUMP Used with table OMACC to display groups and
fields already assigned.
>
OMCLASS
Used to define or change a class for table
OMACC. Once defined, a class name cannot be
deleted, but it can be renamed. Registers and reg-
ister groups are added to the class using com-
mands OMACCFLD and OMACCGRP.
>
OMACCFLD
Assigns or deletes individual OM register fields to
the accumulating classes.
>
OMACCGRP
Assigns or deletes OM groups to the accumulat-
ing classes that were previously defined by
OMCLASS.
>
OMFORMAT
Similar to the
OMSHOW
command, except that
only one OM group is displayed.
>OMACCKEY Allows the operating company to select specific
tuples within a named group and class for display
or printout.
>OMTOTAL This useful command turns the totalling feature
on or off for a specified OM group.
>OMACCTOT Turns the totalling feature on or off for a specified
class and group.
>OMBR This command—along with parameters, stops,
starts, displays—provides control for buffered
OMs. It can be used when problems arise with
buffered OM reports.
>OMGETGD This command processes the header (H), class
(C), group (G), field (F), and key (K) records
stored at the beginning of the data file. This com-
mand causes a translation database to be built.
Close the requested file in DIRP before issuing
this command.
>
OMPRDUMP
Provides the capability to generate operational
measurement special reports (OMPRSPEC) for
the OM data stored on the tape or disk in the stan-
dard recording format (OMTAPE).
>
OMPRTREP
Requests the printing of the OMPRSPEC report.
>OMPRTSET Sets or queries the time and date parameters for
report generation.
>OMMASTER This command, executed on the CM, allows the
user to configure a node as the central collector
for billing. This is the node (CM, FP2, or the
enhanced input/output controller (EIOC)) on
which the OM accumulation and reporting func-
tions take place. WARNING - Use of the
OMMASTER command causes loss of currently
defined accumulation classes and their data. Also,
do not “break” (use command HX) from the
OMMASTER command.
>OMRESET This command provides for the record count to be
reset only on
reload
restarts.
>
OMREPORT
Allows the capability to query for a list of all
report names in the OMREPORT system and to
request an OM report by SCHEDNO in table
OMREPORT.
>READ Used to query the register content of specified
lines and displays the line information.
>READPX Displays information for INWATS registers asso-
ciated with options INW and 2WW for PX trunks.
>READRESET Queries register content of specified lines, dis-
plays line information, and resets register to zero.
>READRESETPX Displays the information for INWATS registers
associated with options INW and 2WW for PX
trunks, and resets the registers back to zero.
>READVFG Displays the information for INWATS VFGs.
OM commands continue on the next page.