User guide
149
T
I
E
R
II
S
U
P
P
O
R
T
T
O
O
L
S
XPMIST Breakdown for Attendant Console
(TAM-1001-007, PMIST User Guide)
Note: The following examples contain abbreviations and may not
appear exactly as a printout would.
XPMIST Example:
INCOMING 13:51:05.3 NODE TYPE= TM_NODE DM_REPORT_MSG
NN= 0031 TN= 0007 MSGTAG= 01 ROUTE= 4080 ERR= 00 LENGHT= 13
AGENT= DMODEM 22
5F 00 00 07 01 14 12 0F 15
6C 1C
CALLID= 925734
digits dialed: 5306
key hit message 1 + 4 -> 5
1 + 2 -> 3
0 + F -> 0
1 +5 -> 6
XPMIST Example:
INCOMING 13:51:05.3 NODE TYPE= TM_NODE DM_REPORT_MSG
NN= 0046 TN= 000F MSGTAG= 01 ROUTE= 4000 ERR= 00 LENGTH= 0F
AGENT= DMODEM 10
5F 00 00 03 01 3C
1C
CALLID= 689675
key number from “Internal to Physical Key Mapping”
diagram: 3C -> key 29 in Table FNMAP
key hit message
XPMIST Example:
00 38 CALLXEC C3
A U T H : I N P U T
02 42 CDTB 1D 30 90 97 07 41 55 54 48 3A 20 49 4E 50 55 54 20 20 20
20 20 87 00 00 C0 00 96 10 0C
display message — ASCII characters
XPMIST Example:
lamp messages
00 38 CALLXEC C3
02 42 CDTB0B 30 90 82 02 82 7B 88 00 0C 00 00
02 -> 0000 0010: lamp 0 — 120 IPM
7B -> 0111 1011: lamp F — on
lamp states: state
000 = off lamp
001 = 60 IPM
010 = 120 IPM
011 = on
111 = 20 IPM
lamp numbers (from CI):
>
AC <console CLLI> DISPL LAMPS
Decimal to HEX to Binary Chart
Decimal HEX Binary
0 0 0000
1 1 0001
2 2 0010
3 3 0011
4 4 0100
5 5 0101
6 6 0110
7 7 0111
8 8 1000
9 9 1001
10 A 1010
11 B 1011
12 C 1100
13 D 1101
14 E 1110
15 F 1111