UPG and Morningstar settings
Page 3
Copyright 2020 Morningstar Corporation/All Rights Reserved
Battery HVD/High Voltage Disconnect/Reconnect = Enable/ 14.7 V/ 14 V Max
Regulation Limit = Not enabled
Battery Current Limit = Amp Hour Battery Rating (< Max allowable charge current) for PS‐MPPT only
Load Settings (where applicable for controller models which include LVD settings): Low Voltage
Disconnect (LVD) = 12.5 V
Low Voltage Reconnect (LVR) = 13 V Delay
Before LVD = 1 minute
Load Current Compensation .005 Ω (V/A) (reduces LVD Voltage based on size of load: 0.005 suggested)
HVD/High Voltage Disconnect/Reconnect: Enable/ 15 V/ 14 V (Load HVD)
Note:
Many lithium batteries include a BMS that can implement an internal battery disconnect in the event of a deep discharge or
high voltages in order to prevent permanent damage to the battery chemistry. It is important that proper low voltage load
disconnect settings and charge settings are used to prevent this from occurring during discharging and charging. Damage to the
controller due to a battery disconnect during charging is typically not covered under warranty. Incidental damage to loads is
also not covered under warranty. Adjustments to these controller settings (raising the LVD setting, lowering the
Absorption/Float voltages or shortening the Absorption time settings) or changing system parameters should be considered.
For more information regarding settings adjustments please contact Morningstar at support@morningstarcorp.com.
Battery Charge LED Indications (Not intended for accurate SoC measurement):
LED G –> G/Y 75%+ = 13.3 V
LED G/Y –> Y 50% ‐ 74% = 13.1 V LED
Y –> Y/R 25% ‐ 49% = 12.9 V
LED Y/R –> R 10% or below = 12.7 V
(More information regarding these settings provided by Morningstar)
These custom settings are available for the Morningstar controllers listed below:
SunSaver MPPT
ProStar MPPT (includes low temperature foldback to limit the max. charge current)
ProStar (PWM) Gen 3 (includes low temperature foldback to limit the max. charge current)
Communications hardware required for programming Custom Settings with MSView:
SunSaver MPPT, ProStar MPPT, ProStar (Gen 3)
UMC‐1 USB MeterBus Adapter‐ **********.morningstarcorp.com/products/usb‐meterbus‐adapter/
MSC PC RS‐232 MeterBus Adapter‐ **********.morningstarcorp.com/products/pc‐meterbus‐adapter/
EMC‐1 Ethernet MeterBus Converter‐ **********.morningstarcorp.com/products/ethernet‐meterbus‐