UPG and Morningstar settings

Page 2
Copyright 2020 Morningstar Corporation/All Rights Reserved
Note: At the time of this publication single 12V battery system configurations are supported with this model. For information
regarding battery bank configuration options, please contact the battery manufacturer.
LFP1260, 12V 6Ah; we recommend the SunKeeper SK‐6 or ProStar MPPT PS‐MPPT‐25 (custom programmed)
No Temperature Compensation and maximum charge current 6 amps.
LGP12120, 12v 12Ah; we recommend the SunKeeper SK‐6/SK‐12 or ProStar MPPT PS‐MPPT‐25 (custom programmed)
No Temperature Compensation and maximum charge current 12 amps.
LFP12180, 12v 18Ah; we recommend the SunKeeper SK‐6/SK‐12, SunSaver MPPT SS‐MPPT‐15 (custom programmed),
ProStar PS‐15 (custom programmed) or ProStar MPPT PS‐MPPT‐25 (custom programmed)
No Temperature Compensation and PS‐MPPT‐25 maximum charge current 15 amps.
For optimal integration, the recommended settings (based on 12V nominal values) are as follows:
SunKeeper Charge Settings (non‐programable):
Absorption Voltage = 14.1 V
Absorption Time = 120 minutes
Float Voltage = 13.7 V
Temperature Compensation: Disabled (Cut blue Temperature Compensation Wire Loop)
Please note that SunKeeper controllers do not include Low Voltage Disconnect (LVD).
ProStar, ProStar MPPT and SunSaver MPPT Charge Settings (based on 12V nominal values):
Models:
PS‐MPPT‐25 ‐ LFP1260, LGP12120 and LGP12180
PS‐15 and PS‐15 ‐ LGP12180 only
Absorption Voltage = 14.1 V
Absorption Time = 20 minutes
Absorption Ext = Not enabled
Temperature Compensation = 0.0 V/deg C (Disabled)
Low Battery Temperature Foldback = Optional (High limit = 2 deg C, Low limit = 0 deg C) with ProStar
and ProStar MPPT only
Battery Service Reminder = Not enabled
Float/Float Voltage/Timeout = Enable/ 13.5 V / 30 minutes
Float Cancel = Not enabled
Equalize = Not enabled