Specifications
GETTING STARTED
The measurement system
In the following way you connect the system to
learn how to handle it. For the description of each
laser, measuring unit etc, see chapter A.
1. Mount/place the equipment with suitable
fixtures on the measurement object.
2. Connect the cable to the display unit.
3. Connect the other end of the cable to any
measuring unit or detector. NOTE! You can use
any of the two connections on the units.
4. If you are using a shaft alignment system,
connect the other cable between the measuring
units S and M.
5. Start the display unit by pressing . The first
thing displayed is the program menu. Start the
desired program by keying in the program number.
The picture shows two
measuring units (S, M)
connected to the display unit.
Shift to Program-menu page 2 by pressing
To get to the Main menu, press
Return to previous page by pressing the Menu-
button once again.
(Possible in any situation, also during measurement.)
The first line of the Main menu says “Units found:”
shows whether the display unit is in contact with
all of the connected measuring units.
NOTE! If you connect two measuring units S and
M the laser lights up when a program is started. If
you have a detector and a separate laser trans-
mitter you start the transmitter by pressing its On-
button.
Rough alignment before measuring
6. Now aim the laser at the detector.
Start by aiming the laser at the closed target. (For
detailed description, see chapter C, “Rough
alignment” for shaft alignment, and each program
for other measurements.)
7. Open the target.
8. Enter the required distances as prompted by the
system.
9. Continue the measurement as described on the
display.