Instructions / Assembly
Outside fac
e of th
e door
Jamb
Door
2-7/16’’
2-3/4’’
2-1/8’’ hole
Inside face
of the door
Outside face
of the door
TEMPLATE FOR INSTALLING KIL KEY IN
LEVER AND RIM EXIT DEVICE
FOLD HERE FROM JAMB
Inside face of the door
NOT TO SCALE
FOR MOUNTING
END COVER
40’’ ABOVE FLOOR
2-7/16’’
25/32’’
4-21/64’’
3-25/32’’
2-3/4’’
27/32’’
9/32’’
CENTER
LINE
Drill
2-1/8’’
hole
ROLLER
STRIKE
(A)UL Listed UH-E-RIMBAR-Drill & tap for (6) 1/4’’x20 machine screws for Rim Exit Device and Drill & tap for (3) 1/4’’x20 machine screws for
Roller Strike OPTIONAL for UL Listed UH-E-RIMBAR:
Drill (6) 3/16’’ Pilot Holes for Self Tapping machine screws or wood screws for Rim Exit Device and
Drill (3) 3/16’’ Pilot Holes for Self Tapping machine screws or wood screws for Roller Strike
(B)For UL Fire Rated UH-E-FRTIMBAR-Drill 9/32”holes inside and 3/8” holes outside for the (6)thru bolts and drill & tap for(3) 1/4”x20 machine
screws for Roller Strike
NOTE:
Backset of 2 7/16”from jamb to center or
2 3/4”from door edge to center is acceptable.
Strike shim can be used or not used to make
adjustments to the roller strikes projection to
compensate for doors with different backsets.
B
Drill two 3/8’’
holes 1’’ deep
on vertical
center line on
outside door
face only for
the two
alignment studs.
(
)
When installing Rim Exit device and Vertical Rod Exit devices
on a pair of doors, a Double Door Strike (DDS) is required.
(Available by special order).For complete template information,
please refer to the DDS template.
Custsupport@universalhardware.com