Datasheet
252524 25
VM107:
p25
1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 0
Controllers / switches
This control circuit is ideal for the accurate
control of DC motors, lighting levels, small
heaters as well as other applications.
• The circuit converts a DC voltage into
a series of pulses, such that the pulse
duration is directly proportional to the value
of the DC voltage.
• The great advantage of such a circuit is
that almost no power is lost in the control
circuit.
• Protected against overload and short
circuit.
• power supply: 8 to 35VDC
• maximum output current: 6.5A
• input voltage: between 2.5 and 35VDC
• dimensions: 85 x 48 x 45mm /
3.4 x 1.9 x 1.8”
K8004
Designed to control AC motors with carbon brushes (drilling machine, vacuum cleaner, saw, …).
• High torque, even at low r.p.m.
• May also be used for low voltage loads (24V).
• Supply and load circuit electrically isolated from one another.
• voltage supply: 110-240V
• load voltage: 24-240VAC / 5.5A max.
• adjustable minimum r.p.m.
• low interference level
• range: 5-95%
• PCB dimensions: 130 x 75mm / 5.1 x 3”
K2636
Allows single-button operation of both fan and lighting.
• Features automatic fan turn-off with adjustable delay for use in
e.g.kitchen or bathroom.
• suitable for most types of fans. solid state switching with noise
suppression. can be connected to existing installation. LED
function indication.
K8041
The power saver turns off your
equipment after a preset time.
• It helps you save money and
it increases safety.
• available timers: 1h / 2h / 4h
/ 8h / 24h
• relay output: 10A / 240VAC
max
• power supply: 100 - 240VAC
• dimensions: 65x50x26mm /
2.56 x 1.97 x 1”
K8075
You forget to turn off the tap, the washing machine leaks, the water level in your aquarium
drops, the water tank is empty or suddenly overflows, there’s water in your cellar, etc.
• These things happen and when they do, they often cause a lot of trouble and do a lot
of damage.
• Prevention is still better than cure and that’s where this kit comes in.
• This multifunctional device is easy to use in a variety of applications : 1) LED control
of set fluid level : LOW, MIDDLE, HIGH ; 2) Controller : the relay automatically switches
a pump and/or valve to keep the fluid level between the LOW and HIGH marks ; 3)
Alarm : if the sensor detects a level which is too high or too low (selectable), the relay
will operate a bell or another alarm device.
• power supply: 12-14VAC or 16-18VDC / 100mA
• relay output: 240V / 3A max.
• dimensions:
• controller PCB: 104 x 60mm / 4.1 x 2.4”
• sensor PCB: 104 x 25mm / 4.1 x 1”
K2639
Miniature timer for all applications requiring a delay of up
to 60 minutes.
• The control range may be adjusted.
• power supply: 12VDC / 55mA
• relay: 3A / 220V switchable
• time interval (without modifications): adjustable from 0
to 15 minutes
• PCB dimensions: 38 x 69mm / 1.5 x 2.7”
K2579
small and compact unit. operate output relay by waving
hand or object in front of unit. no touching required.
adjustable sensitivity. status led indicators. momentary
(pulse) or toggle (ON/OFF) mode. Perfectly suited for
our Velbus system and our K8006
home bus system. Use for detection in DIY
projects (not suited for very dark object
detection). Comes complete with snap-in
enclosure. Type VMBFBI. fits Velleman
VMBFDG and VMBFLG frames
power supply: max. 12VDC/100mA
• output relay rating: 3A/24VDC
• LED indication
• dimensions (wxhxd): 21x47x41mm /
0.8x1.85x1.6”
K8092
very practical for counting people or parts, scorekeeping, ....
counts up or down. count input through on-board push buttons or
by external pulses. display modes: normal or time (hh:mm and
mm:ss). an internal oscillator allows time measurement. a memory
function constantly compares the current value with a preset value
and activates an output for as long as both are equal. self diagnostic
at power up. comes with easy board-to-wire connector (20cm
wire). optional bezel enclosure: B8035
counter input voltage: 3...12Vdc (normal dry contact also possible)
• EQUAL output: 5Vdc / max. 50mA
• max. counting speed: 200 / sec. (2 / sec. with long debounce
delay)
• max. count: 4 digits (9999 / 23h59m / 59m59s)
• power supply: 9 - 12Vdc or transformer 2 x 9Vac / 300mA,
type : 209005
• power consumption: 150mA max.
• dimensions: 125 x 75mm / 4.9 x 3”
K8035
mounted version
K8092
Optical proximity switch
K2639
Liquid level controller
K8004
Dc to pulse width modulator
K2636
Speed controller
K8075
Power saver / timer
K8035
Multifunctional up/down counter
K2579
Universal start/stop timer
K8041
Fan timer