9.5 Thermal Shock
The unit under evaluation (no batteries or power) will be subjected from -20°C to 60°C
for 5 cycles with a dwell time of 1 hour at high and low temperature (as shown below).
Functional tests will be performed after the HRC has stabilized at normal room
conditions for two hours.
9.6 Drop Test
The unit under evaluation must withstand one drop from 36 inches on six surfaces and
four
corners onto hardwood flooring (suggested 0.75" thick oak). For further
specification details, see UEI Spec. #0005-0005.
For a product with three batteries or less, the battery door and batteries should not be
dislodged during the test.