User's Manual
Viewsonic Tweety RF Remote Rev 2.9A November 05, 2001
Universal Electronics Inc. Confidential Page 4 of 63
Rev 2.0 3.1.1
3.3
3.1.3
3.1.4
3.1.5
3.4
1.1, 4,
6.1.1
4
4.1
Changed IC package to QFP (from DIE)
Changed MUTE to RESYN in “Conventions and Notations”
Changed PCB material from FR4 to Paper Phenolic
Item 14- Added URC number
Item 3- No FCC testing by UEI
Revised “Remote UEI Key and Pointing Device Data Packet”
Changed RF Operating Band range to 2446.7 – 2464.3MHz
Table 2, Rqmt No. 4.10 – Changed to “Simplex”
Added Manchester Data Coding table
Lee
Rev 2.1 5.1.1
5.1.2
5.1.3
Revised RF Channel and Operating Bands
Revised RF Channels and Frequencies
Added Pulse Width Timing section
JE
2.2 2.1.1
3.1.5
3.1.6
10.2
Added comment that NMB receiver Spec 0.9 takes precedence
Modified item 3 to state FCC certification will be done by Optoma
with UEI for support only.
Item 1 (Batteries Included) has been changed from No to Yes-Bulk
Item 2 (Batter Cover) Rating Label required has been changed from
No to yes installed in specified area.
Item 10 Device Label in addition to packaging changed from Yes
to Installed on Unit
Changed FCC requirement to read as follows “Optoma will certify
the complete unit with remote and keyboard.
With documentation and possible engineering support to Optoma
from UEI.
JE
2.3 3.4 &
3.4.7.1
3.4.6.1
5.1.2
Added provision to allow for using the varapoint mouse and the left
and Right select keys simultaneously
Add notes on power state for entering Factory Test modes and E2
Revised RF Channels and Frequencies
JE
2.4 5.1.2 Revised RF Channel Data to match the transmission table JE
2.5 7.6
11
3.2.4,
3.4.6.2
Updated Color Specification Chart
Imported revised rendering dated 8/15/01 Style A rev 3.0
Updated Key charts for Smart and Enter Key
JE
2.6 3.4
3.4.3
3.4.5
4.12
Added Definition for Mouse Right and Left while used in conjunction
with the mouse
Updated Device Number Setup definition
Updated E2 Initializtion Definition
Changed power source from 2.2VDC to 2.2VDC
JE
2.7 3.2.4,
3.4.6.2,
7.6
11
Updated key-tables to reflect silk-screening changes
Updated Rendering imported with silk-screening changes
JE
2.8 11 Updated Rendering with new Vara-touch pointer JE
2.9 3.2.4,
3.4.6.2
3.4
Added Break Data ‘F6’ for the Sync Key
Added Break Data ‘F6’ for the Sync Key
Revised Comment in Re-Sync Section in regards to no Break-Code
being sent after the Re-Sync key was released.
JE
2.91 1.1
4.9
Corrected Frequency
Output power is –18dbm
RM










