User Manual
Figure 55. Device and Program condition select.
The program state is set to True when the program enters the Then path and False when it
enters the Else path. Folder conditions can be set based on the program state. This state is also
reported in the Status column in the program summary table.
Select ‘Add to IF’ button to add the triggers to the condition section.
8.1.4.3 Action
The action button adds the action information in the ‘Then’ and ‘Else’ section of the program. It is
defines the action taken after the condition is met or the trigger occurs.
An action can be setting a device to a defined state that is ON/OFF or set level. The type of
action is dependent on the device type. The devices that are supported are INSTEON or X10
compatible devices.
Besides setting a device, an action can also be to:
a. Run or Stop a Program.
b. Notify the addresses in the Recipients List.
c. Wait for a specified period or randomly within the specified period.
d. Repeat for a specified period or for a set number of times. Action statements
following the Repeat action are indented. They will be repeated per the specified
period or the set number of times.
The repeat and wait actions have a random option. This is set by selecting the Random check
box. A random value from 1 to the entered value will be randomly chosen each time the action is