User Manual
The ISY creates groups by creating a scene. This is accomplished by selecting Mutually
Exclusive Button on the GUI and dragging the device buttons into the Mutually Exclusive Button 1
or 2. Refer to Figure 35.
Figure 35. Mutually Exclusive Buttons.
Button Toggle Mode sets the button state to toggle from ON to OFF and vice versa, or stay
always ON, or always OFF. Assigning a button for toggle OFF sets it to either always ON or
always OFF mode setting. The ISY will ask you to physically set the button to ON or OFF (key
status LED ON or OFF) in the process. Refer to the KeypadLinc User’s Manual Toggle Mode
section for more information.
Select and hold the slider control, move it to the level or ramp rate your desire. As you change
these settings the device will proportionately change the lamp brightness or ramp up/down time of
the lamp.
The tree at the right side of the view pane shows the scenes the device belongs to and as a
controller switch showing which devices it controls.
Right mouse clicking on an INSTEON device node, presents a menu as depicted in Figure 36.
Figure 36 – Device Menu