User's Manual

UL-801 Installation Manual
Page 313
23-20-06 15 December 2011
(2) Sheet 2 of 2 - 4/5” FPCDU/MCDU
TP
9A
9B
RS-422 DISPLAY
DATA TX #3
RS-422
DISPLAY
DATA RX
9C
9D
RS-422 DISPLAY
DATA RX #3
RS-422
DISPLAY
DATA TX
P3
RS-422
DISPLAY
DATA RX
RS-422
DISPLAY
DATA TX
P3
E
F
B
C
D
E
F
B
C
D
SHIELD GND
SHIELD GND
5
5
4
4
1 REFER TO APPLICABLE TECHNICAL MANUAL FOR PORT CONFIGURATIONS AND PIN ASSIGNMENTS.
2 CONFIGURATION MODULE IS MOUNTED ON THE REAR OF THE UL801 RACK.
3 IF FMS #1 IS NOT INTERFACED TO THE UL801, THEN CONNECT FMS #2 TO MP1C AND MP1D INSTEAD OF
THE WIRING (MP2C & MP2D) SHOWN ABOVE.
4 THE P3 CONNECTOR IS AMPHENOL P/N MS27473T12F8SC AND IS INCLUDED IN THE APPROPRIATE
UNS-1D INSTALLATION KIT.
DISCRETE INPUT ACTIVE STATE IS CONFIGURABLE TO EITHER OPEN OR GROUND.
IT IS RECOMMENDED THAT DOOR 1 OPEN DISCRETE BE USED IF ONLY ONE DOOR DISCRETE IS TO BE CONFIGURED.
6
7
ALL WIRING IS TO BE 22 AWG UNLESS OTHERWISE INDICATED.
NOTE:
UL-801
(P/N 10801-XX)
----CONTINUED----
5
THE 5 FPCDU, P/N 1018-2-X10, SUPPORTS BOTH UNILINK TEXT AND WEATHER GRAPHICS (RS-422 DISPLAY
DATA). OTHER 5 FPCDUs, P/N 1018-X-X00, SUPPORT UNILINK TEXT ONLY DISPLAYS.
8
BOTH 4 AND 5 FPCDUs ARE WIRED IN THE SAME MANNER.
8
#1 4"/5 FPCDU/MCDU
(P/N 1117-X-X1X,
P/N 1018-X-X1X,
P/N 1025-XX-XXX)
#2 4"/5 FPCDU/MCDU
(P/N 1117-X-X1X,
P/N 1018-X-X1X,
P/N 1025-XX-XXX)
A
B
A
B
A
B
A
B
A
B
A
B