User's Manual

UL-801 Installation Manual
Page 301
23-20-06 15 December 2011
Installation and Wiring
1. Installation Considerations for UniLink Mounting
A. UniLink Mounting
The UniLink may be installed inside or outside of the pressure vessel. The UniLink must not
be mounted next to excessive heat producing equipment or in such a way as to impede
normal convection cooling and it must not be mounted with its rear connector up. The
UniLink may be mounted in any rotational direction in an upright position. The UniLink rack
must be grounded to the airframe by use of proper bonding methods. This provides a positive
grounding of the rack to which data shields may be connected.
2. Wiring Diagrams
The following wiring diagrams show connections between the UL-801 and other avionics
equipment used in typical installations. Refer to the appropriate FMS technical manual for
additional required wiring.
These diagrams include our suggested choices for configurable discretes and
communications ports but the choice is left up to the discretion of the installer. Mark the
configuration worksheets to show your actual installation. Configuration worksheets are
found in the System Data Installation section of this manual.
NOTE: The FMS must have SCN 1000.5/1100.5 or later in order to utilize FANS.