User's Manual

UL-801 Installation Manual
Page 109
23-20-06 15 December 2011
Conditions
DO-160F
Section #
Category Description of Conducted Tests
Salt Fog 14 X
Not tested—Equipment not subjected to salt
atmosphere.
Magnetic Effect 15 Z
Actual class will be measured. (The distance required to
cause a compass needle deflection of one degree is
measured and must be less than 0.3 meter to be
considered compliant with Category Z.)
Power Input 16 Z
DC generator systems with or without a battery. Not
designated to transmit under emergency electrical
system conditions.
Voltage Spike 17 A
Equipment installed where high degree of protection
against voltage spikes is required.
Audio Frequency
Conducted Susceptibility
18 Z
Induced Signal
Susceptibility
19 ZC
Equipment intended for operation where interference
free operation is required on an aircraft whose primary
power is constant frequency or DC.
Radio Frequency
Susceptibility (Radiated
and Conducted)
20 R HIRF conditions are part of normal environment.
Emission of Radio
Frequency Energy
21 M
Lightning Induced
Transient Susceptibility
22
A3 G33
J33
Pin test performed to level A3; shielded cable bundle test
performed to level J33; unshielded cable bundle test
performed to level G33.
NOTE: The pin test was performed to level A3 except
for the Ethernet signal pins which were tested to
Level A2.
Lightning Direct Effects 23 X
Icing 24 X
Electrostatic Discharge 25 A
Flammability 26 X