User's Manual
UL-801 Installation Manual
Page 510
23-20-06 15 December 2011
General Error Messages
Text Action/Description
STATUS TIMEOUT LSK [count, first/last
occurrence]
No action required. Protocol errors are automatically
corrected, usually with no impact to the user. If
condition is frequent, examine connection between the
printer and UniLink.
ENQ TIMEOUT LSK [count, first/last occurrence]
RECORD TIMEOUT LSK [count, first/last
occurrence]
RECORD RESEND LSK [count, first/last
occurrence]
PRINTER FAIL LSK [count, first/last occurrence]
DOOR OPEN LSK [count, first/last occurrence]
TEST LSK [count, first/last occurrence]
INIT LSK [count, first/last occurrence]
OVERRUN LSK [count, first/last occurrence]
BUSY LSK [count, first/last occurrence]
INVALID CTS LSK [count, first/last occurrence]
ERASE FAULT LSK [device name, count,
first/last occurrence]
If condition is recent or frequent for a particular device,
examine connection between the graphics display
device and UniLink.
TOO MANY FAILED SLOTS LSK [device name,
count, first/last occurrence]
UNEXPECTED EOF LSK [device name, count,
first/last occurrence]
UNKNOWN IMAGE FORMAT LSK [device
name, count, first/last occurrence]
GIF ERROR LSK [device name, count, first/last
occurrence]
TRANSMIT FAIL LSK [device name, count,
first/last occurrence]
INVALID GX HEADER LSK [count, first/last
occurrence]
If condition is recent or frequent, examine connection
between telephone system and UniLink.
VDL MODE A NOT SUPPORTED
Cycle power once to the VDR. If condition persists,
replace VDR or contact UASC.
VDL MODE 2 NOT SUPPORTED
Cycle power once to the VDR. If condition persists,
replace VDR or contact UASC.
VDR TX WARN FAULT
Cycle power once to the VDR. If condition persists,
replace VDR or contact UASC.
VDR STATUS FAULT
Cycle power once to the VDR. If condition persists,
replace VDR or contact UASC.
CTRL PROTOCOL CMU ERROR
Cycle power once to the VDR. If condition persists,
replace VDR or contact UASC.
CTRL PROTOCOL VDR ERROR
Cycle power once to the VDR. If condition persists,
replace VDR or contact UASC.
ACARSIP CMU ERROR
Cycle power once to the VDR. If condition persists,
replace VDR or contact UASC.