User's Manual
UL-801 Installation Manual
Page 507
23-20-06 15 December 2011
B. General Error Messages
UniLink error messages may be found by using either of the following two processes:
(1) Press the MSG key to see the messages.
a) Press the NEXT key to scroll through the messages.
(2) Press the MAINTENANCE LSK [4L] on the UNILINK MENU 1/2 page.
a) Press the ERROR LOG LSK [4L] on the MAINTENANCE 1/3 page.
NOTE: The Error Log contains all error messages including configuration
error messages. The messages found when pressing the MSG key are
only applicable to configuration errors.
b) Press the NEXT key to scroll through the messages.
General Error Messages
Text Action/Description
FMS1 INOP
Cycle power to UniLink and FMS1. If condition persists
contact UASC.
FMS2 INOP
Cycle power to UniLink and FMS2. If condition persists
contact UASC.
FMS3 INOP
Cycle power to UniLink and FMS3. If condition persists
contact UASC.
CDU1 DP INOP
Cycle power to UniLink and CDU1. If condition persists
contact UASC. If condition is recent or frequent for a
particular device, examine connection between the
graphics display device and UniLink.
CDU2 DP INOP
Cycle power to UniLink and CDU2. If condition persists
contact UASC. If condition is recent or frequent for a
particular device, examine connection between the
graphics display device and UniLink.
CDU3 DP INOP
Cycle power to UniLink and CDU3. If condition persists
contact UASC. If condition is recent or frequent for a
particular device, examine connection between the
graphics display device and UniLink.
REMOTE CDU1 DP INOP
Cycle power to UniLink and RCDU1. If condition
persists contact UASC. If condition is recent or
frequent for a particular device, examine connection
between the graphics display device and UniLink.
REMOTE CDU2 DP INOP
Cycle power to UniLink and RCDU2. If condition
persists contact UASC. If condition is recent or
frequent for a particular device, examine connection
between the graphics display device and UniLink.
REMOTE CDU3 DP INOP
Cycle power to UniLink and RCDU3. If condition
persists contact UASC. If condition is recent or
frequent for a particular device, examine connection
between the graphics display device and UniLink.
MFD-LR1
INOP
Cycle power to UniLink and MFD1. If condition persists
contact UASC. If condition is recent or frequent for a
particular device, examine connection between the
graphics display device and UniLink.