User's Manual

UL-801 Installation Manual
Page 506
23-20-06 15 December 2011
2. Error Messages
A complete list of defined error messages is shown in the following tables:
The Pop-up Error Messages table shows the error conditions that result in a pop-up
window error message. These errors are deemed significant enough to warrant
immediate, detailed annunciation.
The General Error Messages table shows the general error messages that may result in a
NEW ERROR MSG advisory alert, as well as the recommended actions for resolution.
The Configuration Error Messages shows possible configuration error messages, as well
as the recommended actions for resolution.
The Hidden Error/Status Messages shows unannunciated error/status messages that are
normally hidden from the error log.
A. Pop-up Window Error Messages
Pop-up Window Error Messages
Pop-up Window Text Condition
FMS/MCDU CONFIG ERROR. CONFIG NOT
SAVED.
User attempt to STORE configuration data that does
not configure the same FMS or MCDU on RX Port 1
and TX Port 1.
FMS/VDR SHARE TX PORT. CONFIG NOT
SAVED.
User attempt to STORE configuration data with an
ARINC 429 transmit port configured to interface to both
a UASC FMS and an ARINC 750 VDR.
FMS/MCDU CONFIG ERROR. CONFIG NOT
SAVED
User attempt to STORE configuration data with both a
UASC FMS/CDU and an MCDU configured together.
UNABLE TO WRITE TO CONFIG MODULE.
User attempt to STORE configuration data with
Configuration Module error.
DISPLAY PROCESSOR FAIL
A configured display processor has failed or
experienced a communication failure, or too many bad
slots have been detected.