Page 432
23-20-06 15 December 2011
C. Storing UniLink Options
When all new or modified UniLink options have been entered, the installer can review the
configuration by pressing the REVIEW LSK [4R] on the UniLink SYS CONFIG 1/4 page.
This provides easy access to review and confirm any configuration warning from the
UniLink.
If all modifications are acceptable, press the STORE LSK [1R]. Wait a few seconds and
press the STORE LSK again. This stores the entered information, and verifies that required
dependencies and consistency exist between the Configuration Data and the software, and
also among the Configuration Data items. UniLink will initialize and the FMS will display
the following message:
UNILINK, LSK [5L], displays in small capitals. Once the UniLink has rebooted and is ready
to process additional information, the word UNILINK redisplays in large capital letters.
Pressing the UNILINK LSK [5L] returns the FMS to the UNILINK MENU.
UNILINK/FMS
COMM ERROR
RESELECT UNILINK
¬UNILINK