User's Manual

UL-801 Installation Manual
Page 431
23-20-06 15 December 2011
Use the completed worksheets, found in the Configuration Worksheets section, and enter that
information into UniLink. Work through all the UniLink menus and make any necessary
modifications for the configuration.
The steps should be performed in the order indicated by the large number in the corner of the
text box.
Some of the items configured are limited to a small number of options that are selectable by
pressing a line select key (LSK). The options appear one at a time in a set sequence and are
included in the text of the step.
Other items that may be configured are limited to more than a few options. These items are
selected by typing the number of the option as presented in a numbered list.
For those items that have many possible configurations, make an entry in a fill-in field. For
example, the ICAO has assigned hundreds of aircraft type designators. These type
designators consist of not more than four characters. On the Aircraft Configuration page the
aircraft type field allows entry of up to four characters.
If an entry field is not highlighted, press the corresponding line select key to move the cursor
highlight to the field.
B. FANS Block Data Transmission
FMS SCN 1000.5/1100.5 or later is capable of transmitting FANS-specific data to support
the UniLink FANS functions. In order to enable the transmission of the FMS FANS-specific
data, ensure the FMS is configured to transmit over the UNS HS429-1 Bus.
1. Press the DATA key to display the DATA 1/4 page.
2. Press the PREV key to display the DATA 4/4 page.
3. Press DATE to highlight the date.
4. Enter 456789 and then press the ENTER key. The date will revert to the actual initialized
date.
5. Press the NEXT key to display the DATA 1/4 page.
6. Press MAINT to display the MAINT 1/1 page.
7. Press CONFIG to display the CONFIG 1/2 page. The EDIT prompt at LSK [1R] is not
normally displayed, but is displayed now because the configuration has been unlocked by
entering the code on the DATA 4/4 page.
8. Press EDIT to replace EDIT with STORE and allow FMS configuration settings to be
changed.
9. Press FMS CONFIG. Access the FMS CONFIG 2/4 page.
10. Press CMU. Enable FANS block data transmission.
11. Press STORE twice to restart the FMS.