User's Manual

UL-801 Installation Manual
Page 425
23-20-06 15 December 2011
SYS CONFIG 2/4 (Continued)
ALERTS
NEW MSG DISC DURATION
(New Message Discrete Duration)
ALERT1
__________________
MS (Max 4 N characters)
(Milliseconds); 100MS
ALERT2
__________________
MS (Max 4 N characters)
(Milliseconds); 100MS
CHIME1
__________________
MS (Max 4 N characters)
(Milliseconds); 100MS
CHIME2
__________________
MS (Max 4 N characters)
(Milliseconds); 100MS
INHIB ON GND
(Inhibit on Ground)
__________________
KTS (Max 3 N characters)
(Knots); 50KTS
INHIB ALT
(Inhibit Altitude)
__________________
FT (Max 5 N characters)
(Feet); 10,000FT
ALT TYPE
(Altitude Type)
RADIO
RADIO type may only be
configured when IOP bus
input is used. When
RADIO is configured,
INHIB ALT must be 2500
feet or below.
BARO
AFTER OFF
Alerts are turned off during
this configured time
duration. 0MIN disables
this timer, which allows
the alerts to occur only
above the configured
INHIB ALT value.
__________________
MIN (Max 2 N characters)
(Minutes); 5MIN
The timer is off if set to 0MIN.
Press NEXT. The SYS CONFIG 3/4 page displays.