UL-801 Installation Manual
Page 414
23-20-06 15 December 2011
d) ARINC TRANSMIT
NOTE:
If any ARINC TX port is selected as 741 SDU, then SAT must be
selected as the Normal or Alternate option in the PRIORITY (SYS
CONFIG 1/4) option page.
If an ARINC TX choice is displayed in small print and there is no arrow
pointing to an LSK that selection is not available for use.
VOX tune bus can only be configured for one port.
ARINC TX 1/3
PORT 1
(A) Middle Plug 1A
(B) Middle Plug 1B
NOTE: Only TX port with a default.
FMS/CDU1 FMS/CDU2 FMS/CDU3 740 PRINT
741 SDU VOX TUNE VM CMC 604 CMC
MCDU1 MCDU2 MCDU3 CVR
702 FMS1 702 FMS2 702 FMS3 750 VDR
TEST NOTE: Test is used by the Engineering Development
only. DO NOT CONFIGURE.
PORT 1 SPEED
LOW NOTE: LOW is the only configurable option.
PORT 2
(A) Middle Plug 2A
(B) Middle Plug 2B
Ports 2-16 have no default settings.
FMS/CDU1 FMS/CDU2 FMS/CDU3 740 PRINT
741 SDU VOX TUNE VM CMC 604 CMC
MCDU1 MCDU2 MCDU3 CVR
702 FMS1 702 FMS2 702 FMS3 750 VDR
TEST
PORT 2 SPEED
LOW
HIGH
PORT 3
(A) Top Plug 15A
(B) Top Plug 15B
FMS/CDU1 FMS/CDU2 FMS/CDU3 740 PRINT
741 SDU VOX TUNE VM CMC 604 CMC
MCDU1 MCDU2 MCDU3 CVR
702 FMS1 702 FMS2 702 FMS3 750 VDR
TEST
PORT 3 SPEED
LOW
HIGH
Press NEXT. ARINC TX 2/3 displays.
PORT 4
(A) Top Plug 11A
(B) Top Plug 11B
FMS/CDU1 FMS/CDU2 FMS/CDU3 740 PRINT
741 SDU VOX TUNE VM CMC 604 CMC
MCDU1 MCDU2 MCDU3 CVR
702 FMS1 702 FMS2 702 FMS3 750 VDR
TEST
PORT 4 SPEED
LOW
HIGH
PORT 5
(A) Middle Plug 5B
(B) Middle Plug 5C
FMS/CDU1 FMS/CDU2 FMS/CDU3 740 PRINT
741 SDU VOX TUNE VM CMC 604 CMC
MCDU1 MCDU2 MCDU3 CVR
702 FMS1 702 FMS2 702 FMS3 750 VDR
TEST
PORT 5 SPEED
LOW
HIGH