User's Manual
UL-801 Installation Manual
Page 333
23-20-06 15 December 2011
R. UL-801 to MFD-640 – High Resolution (MFD SCN 1011.4.8 or later)
MFD-640
P/N 6402-XXXXX-XX
UL-801
(P/N 10801-XX)
TP
P1
RETURN/SHIELD
B
A
B
A
1
RS-422 TX #1
RS-422 RX #1
7A
7D
7C
7B
1
USE ANY AVAILABLE RS-422 PORT. PORTS DEPICTED ARE EXAMPLES. A MAXIMUM OF TWO HIGH-RESOLUTION DISPLAYS MAY BE USED.
SELECT SERIAL
PORT 4 SELECT HI-RES DISPLAY 1
I/O CONFIG:
UNILINK CONFIGURATION
RS-422 MENU
J1-58, J1-57 RX FUNC: UNILINK PRIMARY
RX NUMBER: SYSTEM 1
RS-422 TX CHANNEL MENU
J1-47, J1-46 TX FUNC: UNILINK
J1-58, 47, J1-57,46 SPEED: 38400
MFD-640 CONFIGURATION
CONFIGURATION MAIN MENU
UNILINK NODE ID: 35
BAUD RATE: 38.4K
GRAPHICS CONFIGURATION
CDU/MFD BAUD RATE SELECT 19.2 KBPS
CDU1 GRAPHICS DISPLAY ON SEE THE EXAMPLES BELOW
CDU2 GRAPHICS DISPLAY ON SEE THE EXAMPLES BELOW
CDU3 GRAPHICS DISPLAY ON SEE THE EXAMPLES BELOW
1
NOTE: UNILINK HIGH RESOLUTION CONFGURATION SETTINGS REQUIRE MFD-640-SCN 1011.4.8 OR LATER.
THE UNILINK HIGH RESOLUTION MFD MUST BE CONFIGURED AS DEFINED BELOW.
EXAMPLE 1 EXAMPLE 2
CDU1 GRAPHICS DISP ON CDU1 GRAPHICS DISP ON
CDU, RCDU, HR1 CDU, FPCDU, HR1
CDU2 GRAPHICS DISP ON CDU2 GRAPHICS DISP ON
CDU, HR2 CDU, HR2
CDU3 GRAPHICS DISP ON CDU3 GRAPHICS DISP ON
CDU
ANY ADDITIONAL SELECTIONS WILL RESULT IN AN ERROR MESSAGE.
A
B
RS-422 DISPLAY
DATA TX #4
A
B
RS-422 DISPLAY
DATA RX #4
46
58
47
57