User's Manual
UL-801 Installation Manual
Page 328
23-20-06 15 December 2011
NOTES continued
5
REFER TO APPLICABLE TECHNICAL MANUAL FOR PORT CONFIGURATIONS AND PIN ASSIGNMENTS.
6
IF FMS #1 IS NOT INTERFACED TO THE UL801, THEN CONNECT FMS #2 TO MP1C AND MP1D IN LIEU OF MP2C AND MP2D SHOWN ABOVE.
11
CONNECT TO AN AURAL ALERTING DEVICE OR AN AURAL WARNING GENERATOR. USE SONALERT P/N SCE028LD2TT1B OR EQUIVALENT.
7
WHITE ATC LETTERING RECOMMENDED. USE ANNUNCIATOR P/N EATON 582-10 A0 B0 C3 F4 L5 N1 (D) P12,12 ATC OR EQUIVALENT.
8
ANY AVAILABLE DISCRETE OUTPUT PIN MAY BE USED.
13
OPTIONAL: CPDLC CNECT ANNUNCIATOR. LABEL AS REQUIRED.
12
OPTIONAL: CONFIGURE DISCRETE OUTPUT FOR CPDLC CNECT (CONNECT).
9
CONFIGURE DISCRETE OUTPUT FOR FANS VISUAL.
10
CONFIGURE DISCRETE OUTPUT FOR FANS AURAL.
4
UNS1Lw SUPPORTS BOTH UNILINK TEXT AND WEATHER GRAPHICS USING RS-422 DISPLAY DATA.
3
IT IS RECOMMENDED THAT DOOR 1 OPEN DISCRETE BE USED IF ONLY ONE DOOR DISCRETE IS TO BE CONFIGURED.
WIRING WITHIN THE DASHED LINES APPLIES ONLY WITH FANS ENABLED.
14