User's Manual

UniLink UL-800/801 FANS
SCN 30.X
Operator’s Manual
23-20-06.02 81
December 2011
TEL Media Status Reason
NOCOMM / CONFIG FAIL While CONNECTING with the
ground server, a message is
received saying the configuration
sent by UniLink is invalid. The
SatCom (TEL) system is
permanently shut down. Cycling
UniLink power is required to exit this
state.
NOCOMM / INIT FAIL The SatCom (TEL) system is not
available for operation. One or both
of the following configuration items
are invalid: Aircraft Registration
Number, or Phone Access Number.
NOCOMM / DIALING UniLink exited out of the 5-minute
delay and is in the process of making
another connection attempt.
NOCOMM / PLEASE WAIT TEL SUSPEND has been manually
activated while a connection is in
progress. UniLink is in the process of
shutting down the connection.
NOCOMM / MDM
TIMEOUT
UniLink exited out of the 5-minute
delay and while in the process of
making another connection attempt
the UniLink modem has timed out.