User's Manual
UniLink UL-800/801 FANS
SCN 30.X
Operator’s Manual
70 23-20-06.02
December 2011
6. Press SEND, LSK [4R] to put the message in queue for
transmission.
Immediate and Delayed Reports and Requests
There are over 20 possible report or request pages, categorized as
either Immediate or Delayed.
Immediate Requests and Reports
Immediate uplink requests and reports, listed in Table 1, do not
require a ROGER response and can be fulfilled immediately. If
UniLink receives a valid Data Transaction uplink containing a request,
that request will be added to the RPTS LIST with status pending.
NOTE: Data statuses include:
• Sufficient = UniLink supplies the necessary data on the page
• Insufficient = UniLink cannot supply all the data and it will need
to be entered
• No Data = No data is required for the communication
TABLE 1 – Immediate Reports and Requests
Uplink Requests
Downlink Reports
Display
Display
Data
CONFIRM ALTITUDE
PRESENT ALTITUDE
[altitude]
Sufficient
CONFIRM POSITION
PRESENT POSITION
[position]
Sufficient
CONFIRM SPEED PRESENT SPEED [speed] Sufficient
CONFIRM HEADING
PRESENT HEADING
[degrees]
Sufficient
CONFIRM GROUND
TRACK
PRESENT GROUND TRACK
[degrees]
Sufficient
CONFIRM
ASSIGNED
ALTITUDE
ASSIGNED ALTITUDE
[altitude]
Sufficient
ASSIGNED BLOCK [altitude]
TO [altitude]
Insufficient
CONFIRM
ASSIGNED SPEED
ASSIGNED SPEED [speed] Insufficient
CONFIRM NEXT
WAYPOINT
NEXT WAYPOINT [position] Sufficient
CONFIRM NEXT
NEXT WAYPOINT ETA [time] Sufficient