User's Manual
UniLink UL-800/801 FANS
SCN 30.X
Operator’s Manual
64 23-20-06.02
December 2011
• To enter a Mach value - type M, use the [ + ] key to place a
period, then enter the value. Press [ENTER] and an M will
display after the entered value.
• To enter speed in IAS KPH – enter the speed value (i.e., 235),
then enter KM and press [ENTER]. The entered value will be
followed by KM IAS.
Speed Data Ranges:
Units
Lower Limit
Upper Limit
Resolution
Knots IAS 70 380 10
KPH IAS 100 1370 10
Mach 0.61 6.04 0.01
4. In the TO field, enter top of the desired speed range.
5. Press REVIEW, LSK [4L]. The ATC REVIEW 1/X page will
display showing the entered speeds from the ATC EXP SPEED –
BLOCK page. – “WHEN CAN WE EXPECT (speed value
entered).TO (speed value entered).”
NOTE: If no data was entered in the SPEED or TO fields, the pop-up
window DATA REQUIERED will display
6. Press FREE-TEXT, LSK [3L] and add text as needed.
NOTE: Text is limited to 24 characters on the page (text will not
wrap).
7. Press SEND, LSK [4R] to put the speed negotiation request into
queue for transmission.