User Manual
Table Of Contents
- UAD Powered Plug-Ins
- Introduction
- UAD Installation
- Overview
- QuickStart DVD
- System Requirements
- Supported Hosts
- Latest Information & Software Updates
- UAD Software Installation
- Install Software First
- UAD Hardware Installation
- Authorization
- Authorize Plug-Ins Procedure
- Load Authorization File
- Offline Authorization
- Using Unlicensed Plug-Ins
- Verifying Installation
- Learn More
- Software Removal
- UAD System Overview
- My.uaudio.com
- Using Multiple UAD Cards
- UAD Meter & Control Panel
- Overview
- Launching the UAD Meter & Control Panel Application
- Using the UAD Meter
- UAD Meter Elements
- UAD Control Panel
- System Information Panel
- Plug-Ins Panel
- Configuration Panel
- Help & Support Panel
- Using UAD Powered Plug-Ins
- Tempo Sync
- UAD Delay Compensation
- UAD-Xpander & UAD-Xtenda
- LA-2A and 1176LN
- LA-3A Compressor
- Fairchild 670
- Precision Multiband
- Precision Limiter
- Precision Buss Compressor
- Neve 33609 Compressor
- VCA VU
- Neve 88RS Channel Strip
- CS-1 Channel Strip
- Precision Equalizer
- Cambridge EQ
- Pultec and Pultec-Pro
- Neve 1073 Equalizer
- Neve 1081 Equalizer
- Helios Type 69 Equalizer
- Roland CE-1
- Roland Dimension D
- Roland RE-201
- RealVerb Pro
- DreamVerb
- Plate 140
- Precision Maximizer
- Precision De-Esser
- Precision Enhancer kHz
- SPL Transient Designer
- Nigel
- Introducing Nigel
- Preflex Plug-in
- Preflex Modules
- Gate/Comp Module
- Amp Module
- Amp Controls
- Cabinet Module
- Phasor Module
- Mod Filter Module
- TremModEcho plug-in
- Trem/Fade Module
- Mod Delay Module
- Echo Module
- Moog Multimode Filter
- History
- Index

UAD Powered Plug-Ins Manual - 285 - Chapter 32: Plate 140
Reverb Time
Meters
The Reverb Time Meters display the reverb time of
plates A, B, and C in seconds. The meter for the
active plate model (as specified by the Plate Se-
lect switch) is illuminated.
Note: The meter value can be changed by dragging its “needle” in addition
to its corresponding Damper controls.
Damper Controls
(Reverb Time)
The Damper Controls change the reverb time for
each plate. The range is from 0.5 to 5.5 seconds,
in intervals of 0.1 sec.
Click the buttons to increment or decrement the re-
verb time.
EQ
This group of parameters contain the controls for Plate 140’s
onboard utility equalizer.
It is a two band (low and high) shelv-
ing EQ that uses analog-sounding algorithms for great tonal
shaping options.
The EQ section is independent from the reverb algorithms and
the low cut filter on the modeled plate systems. See “Cut Filter”
on page 289.
The frequency parameters specify the center of the transition
band, which is defined as the frequency at which the level in
dB is the midpoint between DC and the band edge level.
Note: There is one EQ per plug-in instance. Each plate model (A, B, C) within
a preset cannot have unique EQ values.
EQ Enable
Switch
The Plate 140 equalizer can be disabled with the EQ Enable switch. UAD
DSP usage is not increased when EQ is enabled.