User Manual
Table Of Contents
- UAD Powered Plug-Ins
- Introduction
- UAD Installation
- Overview
- QuickStart DVD
- System Requirements
- Supported Hosts
- Latest Information & Software Updates
- UAD Software Installation
- Install Software First
- UAD Hardware Installation
- Authorization
- Authorize Plug-Ins Procedure
- Load Authorization File
- Offline Authorization
- Using Unlicensed Plug-Ins
- Verifying Installation
- Learn More
- Software Removal
- UAD System Overview
- My.uaudio.com
- Using Multiple UAD Cards
- UAD Meter & Control Panel
- Overview
- Launching the UAD Meter & Control Panel Application
- Using the UAD Meter
- UAD Meter Elements
- UAD Control Panel
- System Information Panel
- Plug-Ins Panel
- Configuration Panel
- Help & Support Panel
- Using UAD Powered Plug-Ins
- Tempo Sync
- UAD Delay Compensation
- UAD-Xpander & UAD-Xtenda
- LA-2A and 1176LN
- LA-3A Compressor
- Fairchild 670
- Precision Multiband
- Precision Limiter
- Precision Buss Compressor
- Neve 33609 Compressor
- VCA VU
- Neve 88RS Channel Strip
- CS-1 Channel Strip
- Precision Equalizer
- Cambridge EQ
- Pultec and Pultec-Pro
- Neve 1073 Equalizer
- Neve 1081 Equalizer
- Helios Type 69 Equalizer
- Roland CE-1
- Roland Dimension D
- Roland RE-201
- RealVerb Pro
- DreamVerb
- Plate 140
- Precision Maximizer
- Precision De-Esser
- Precision Enhancer kHz
- SPL Transient Designer
- Nigel
- Introducing Nigel
- Preflex Plug-in
- Preflex Modules
- Gate/Comp Module
- Amp Module
- Amp Controls
- Cabinet Module
- Phasor Module
- Mod Filter Module
- TremModEcho plug-in
- Trem/Fade Module
- Mod Delay Module
- Echo Module
- Moog Multimode Filter
- History
- Index

UAD Powered Plug-Ins Manual - 173 - Chapter 19: Neve 88RS Channel Strip
The available range is –25dB to +15dB. A range of –25dB to –65dB is avail-
able when the –40dB switch is engaged (see “Gate/Exp Threshold –40dB”
on page 173).
In typical use it’s best to set the threshold value to just above the noise floor of
the desired signal (so the noise doesn’t pass when the desired signal is not
present), but below the desired signal level (so the signal passes when
present).
Gate/Exp
Threshold
–40dB
The –40dB button increases the sensitivity of the gate and ex-
pander by lowering the range of the available threshold values.
When –40dB mode is active, the threshold range is –25dB to
–65dB. When –40 is inactive, the threshold range is –25dB to
+15dB.
To activate –40dB mode, click the “pull –40” label text or the red indicator
just below the Threshold control. –40dB mode is active when the red indicator
illuminates.
Gate/Exp Range
(RGE)
Range (RGE) controls the difference in gain between the
gated/expanded and non-gated/expanded signal. Higher val-
ues increase the attenuation of signals below the threshold.
When set to zero, no gating or expansion occurs. The avail-
able range is 0dB to –60dB.
Gate/Exp Fast
The Fast mode switch defines the gate/expander attack time,
which is the duration between the input signal reaching the thresh-
old and processing being applied. Two times are available: 500
microseconds (when Fast is off) and 50 microseconds (when Fast
is active).
To activate Fast mode, click the “pull FAST” label text or the red indicator just
below the Range (RGE) control. Fast mode is active when the red indicator il-
luminates.
Gate/Exp
Release (REL)
Release sets the amount of time it takes for processing to en-
gage once the input signal drops below the threshold level. The
available range is 10 milliseconds to 3 seconds.