User Manual
Table Of Contents
- UAD Powered Plug-Ins
- Introduction
- UAD Installation
- Overview
- QuickStart DVD
- System Requirements
- Supported Hosts
- Latest Information & Software Updates
- UAD Software Installation
- Install Software First
- UAD Hardware Installation
- Authorization
- Authorize Plug-Ins Procedure
- Load Authorization File
- Offline Authorization
- Using Unlicensed Plug-Ins
- Verifying Installation
- Learn More
- Software Removal
- UAD System Overview
- My.uaudio.com
- Using Multiple UAD Cards
- UAD Meter & Control Panel
- Overview
- Launching the UAD Meter & Control Panel Application
- Using the UAD Meter
- UAD Meter Elements
- UAD Control Panel
- System Information Panel
- Plug-Ins Panel
- Configuration Panel
- Help & Support Panel
- Using UAD Powered Plug-Ins
- Tempo Sync
- UAD Delay Compensation
- UAD-Xpander & UAD-Xtenda
- LA-2A and 1176LN
- LA-3A Compressor
- Fairchild 670
- Precision Multiband
- Precision Limiter
- Precision Buss Compressor
- Neve 33609 Compressor
- VCA VU
- Neve 88RS Channel Strip
- CS-1 Channel Strip
- Precision Equalizer
- Cambridge EQ
- Pultec and Pultec-Pro
- Neve 1073 Equalizer
- Neve 1081 Equalizer
- Helios Type 69 Equalizer
- Roland CE-1
- Roland Dimension D
- Roland RE-201
- RealVerb Pro
- DreamVerb
- Plate 140
- Precision Maximizer
- Precision De-Esser
- Precision Enhancer kHz
- SPL Transient Designer
- Nigel
- Introducing Nigel
- Preflex Plug-in
- Preflex Modules
- Gate/Comp Module
- Amp Module
- Amp Controls
- Cabinet Module
- Phasor Module
- Mod Filter Module
- TremModEcho plug-in
- Trem/Fade Module
- Mod Delay Module
- Echo Module
- Moog Multimode Filter
- History
- Index

UAD Powered Plug-Ins Manual - 148 - Chapter 15: Precision Limiter
K-20
In Normal mode, the meter range is –40dB to 20dB with a linear response of
0.5dB per segment. In Zoom mode, the range is –8dB to 20dB with two dif-
ferent linear responses: 0.2dB per segment from –8 to 15dB, and 0.1dB per
segment from 15dB to 20dB.
K-14
In Normal mode, the meter range is –46dB to 14dB with a linear response of
0.5dB per segment. In Zoom mode, the range is –10dB to 14dB, with linear
response of 0.2dB per segment.
K-12
In Normal mode, the meter range is –48dB to 12dB with a linear response of
0.5dB per segment. In Zoom mode, the range is –12dB to 12dB, with linear
response of 0.2dB per segment.
Hold The meter Hold Time switch determines how much time will pass before the
peak values for the main meter and the gain reduction meter are reset. It af-
fects both the peak LED’s and the peak text display.
Values of 3 seconds, 10 seconds, or Infinite (indicated by the lazy-8 symbol)
can be selected.
Clear The meter Peak Clear switch clears the meter peak value display. It affects
both the peak LED’s and the peak text display.
Precision Limiter Latency
The Precision Limiter has a 1.5ms look-ahead window to ensure clipping does
not occur. This look-ahead function results in a slightly larger latency than
other UAD plug-ins. You may use DelayComp or TrackAdv to compensate.
See “Compensating Upsampled Plug-Ins” on page 95 for more information.
Note: Compensating for Precision Limiter is not required if the host applica-
tion supports full plug-in delay compensation throughout the signal path, or
when it is used only on the outputs. See “Host PDC Implementation” on
page 88.