User`s manual
USB Dongle Series Model:UD-731N
UniTraQ International Corp. RoHS compliance.
2011,01, Version 1.1
17
Field Name Example Description
1 Latitude 4250.55899 Latitude in ddmm.mmmmm format
Leading zeros transmitted
2 N/S Indicator
S Latitude hemisphere indicator
‘N’ = North
‘S’ = South
3 Longitude 14718.50849 Longitude in dddmm.mmmmm format
Leading zeros transmitted
4 E/W Indicator
E Longitude hemisphere indicator
'E' = East
'W' = West
5 UTC Time 092204.999 UTC time in hhmmss.sss format (000000.00 ~ 235959.99)
6 Status A Status, ‘A’ = Data valid, ‘V’ = Data not valid
7 Mode Indicator
A Mode indicator
‘N’ = Data not valid
‘A’ = Autonomous mode
‘D’ = Differential mode
‘E’ = Estimated (dead reckoning) mode ‘M’ = Manual input
mode
‘S’ = Simulator mode
8 Checksum 2D