Technical data

Operation
From fabrication date 07/2005 on this series is equipped with an
emergency STOP (2 a) which must be pushed in case of emergency.
After elimination of cause emergency STOP to be unlocked by pulling it
out, before machine can be re-started.
The electric motor starts in star connection and switches over to star-
delta connection after a few seconds. This process is audible. After the
electric motor has switched over to star-delta connection unlock spray
pistol, firmly seize support handle and pull trigger of spray pistol.
When opening the spray pistol, full working pressure is achieved within
a few seconds. At 500 bar the high pressure hose shortens by approx.
3 %. Particularly when working with extra long hoses or on scaffolds,
take care that operators will not be jeopardized.
Observe torque and recoil, as well as shortening of high pressure hose.
Ensure stable foothold.
Fully open water source
Open spray pistol, bleed unit.
Push ON/OFF switch (2).
Be aware of significant recoil. Ensure stable foothold.
Carry out cleaning task.
Pressure/Flow Regulation
Pressure and flow rate can continuously be adjusted as required at the
regulation handle of the control valve (3).
Counter-clockwise: continuous pressure and flow reduction until
minimum capacity
Clockwise: continuous pressure and flow increase up to
Maximum capacity