7. Maintenance schedule
7.1. Reminder of use
The maintenance interval frequency and the operations to be carried out are outlined in the maintenance schedule, given as a guideline.
N.B. the environment in which the generating set is operating determines this schedule.
If the generating set is used in extreme conditions, shorter intervals between maintenance procedures should be observed
These maintenance intervals only apply to generating sets running on fuel, oil and coolant which conform to the specifications given
in this manual.
7.2. Engine
Component Operation
Before
starting
First 100 -
200 hours
50
hrs
6 months
50 - 600
hrs
500 hrs
Engine Check the sealing (1) ●
Oil level Check and Top up ●
Coolant Check the level ●
Radiator
Check the outside and
clean
●
Air filter
Check the clogging
indicator (1-2)
●
Injectors
Tighten to 50Nm (36.88
lbf ft)*
●
Valve clearance Check/adjust * ●
Batteries
Check the electrolyte
level
●
Fuel pre-filter
Drain the water and
sediment
●
Coolant filter Replace (3) ●
Engine oil Drain (4) ●
Oil filter Replace ●
Drive belts Check the voltage ●
* Operation to be carried out by one of our agents.
(1) When operating continuously, the check must be carried out at least every 8 hours.
(2) The air filters must be replaced when the indicator stays in the red zone after the engine is stopped. Special air filters must be
used for extremely dusty conditions.
(3) The filter must never be replaced when the coolant is drained.
(4) The oil service intervals vary depending on the oil grade and the fuel sulphur content (see engine appendix).
Component Operation
1000
hrs
1500 hrs 2000 hrs 2400 hrs 3000 hrs 5000 hrs
Air ducts
Check that they
are sealed
●
Fuel filter Replace ●
Valve clearance Check/adjust * ●
Air filter Clean (5) ●
Engine and equipment
Carry out a
general check*
●
Turbocharger Check* ●
Injectors Check* ●
Coolant Replace ●
* This operation should be carried out by one of our agents.
(5) In extremely dusty conditions, cleaning must be carried out more often.
7.3. Alternator
After 20 hours in operation, check the tightness of all the mounting bolts, the general condition of the machine and the various
electrical connections of the installation.
The bearings fitted on the machine are greased for life to around the service life of the grease (depending on use) = 20 000
hours or 3 years.
Regularly clean the inlet and outlet grid.