Specifications

Fault codes
44
SID 252, Code 2.8.1 Parameter programming
Reason: Memory fault
Reaction: The engine is emergency stopped and can
not be re-started until the fault is rectified.
Action:
•
Turn the ignition off and on, and check if the fault
code remains.
SID 240, Code 2.8.1 Cyclical program test
Reason: Memory fault
Reaction: The engine is emergency stopped and can
not be re-started until the fault is rectified.
Action:
•
Turn the ignition off and on, and check if the fault
code remains.
PID 158, Code 2.9.1 Control unit, voltage supply
Reason: Voltage supplied to actuator exceeds per-
missible limit values.
Reaction: A fault code is generated. The fault code
disappears when the voltage returns to within the per-
missible limit values.
Action:
•
Turn the ignition off and on, and check if the fault
code remains.
PID 158, Code 2.8.2 Reference voltage 1
Reason: Reference voltage for actuator exceeds per-
missible limit values.
Reaction: A fault code is generated. The fault code
disappears when the voltage returns to within the per-
missible limit values (5 V).
Action:
•
Check the voltage supplied.
•
Turn the ignition off and on, and check if the fault
code remains.
PID 158, Code 2.8.2 Reference voltage 2
Reason: Reference voltage for actuator exceeds per-
missible limit values.
Reaction: A fault code is generated. The fault code
disappears when the voltage returns to within the per-
missible limit values (5 V).
Action:
•
Check the voltage supplied.
•
Turn the ignition off and on, and check if the fault
code remains.
PID 158, Code 2.8.2 Reference voltage 3
Reason: Reference voltage for actuator exceeds per-
missible limit values.
Reaction: A fault code is generated. The fault code
disappears when the voltage returns to within the per-
missible limit values (5 V).
Action:
•
Check the voltage supplied.
•
Turn the ignition off and on, and check if the fault
code remains.
116/209