Specifications

43
Fault codes
SID 23, Code 2.5.1 Control rod position sensor,
difference
Reason: Injection pump/actuator has got stuck or is
not connected. Difference between control rod current
value and nominal value exceeds 10%.
Reaction: A fault code is generated. The fault code
disappears when the difference between control rod
current value and nominal value falls below 10%.
Action:
Check the control rod for the injection pumps.
Check the actuator, control rod and injection
pumps. Change as necessary.
Check the cables for the actuator for breaks and
short circuits.
SID 23, Code 2.5.2 Injection pump, auto
calibration
Reason: Automatic actuator equalization is not possi-
ble. Faulty calibration.
Reaction: The engine is emergency stopped and can
not be re-started until the fault is rectified. The regula-
tor can not be activated.
Action:
Check the actuator. Change as necessary.
Check the actuator cables.
Turn the ignition off and on, and check if the fault
code remains.
SID 231, Code 2.7.1 Communication fault, CAN
bus
Reason: CAN controller for CAN bus is faulty.
Reaction: --
Action:
Check the cables.
Check the control unit.
PID 111, Code 2.3.5 Emergency stop, coolant
level
Reason: Low coolant level
Reaction: The engine is emergency stopped and can
not be re-started until the fault is rectified.
Action:
Check coolant level.
Check the sensor cable for breaks and short cir-
cuits.
Check sensor function (if installed).
Change the sensor as necessary.
NOTE! The engine is supplied without a coolant level
sensor.
SID 24, Code 2.5.1 Control rod position sensor
Reason: Actuator not connected. Faulty value from
control rod position sensor in actuator.
Reaction: Engine is emergency stopped. Actuator
can not be controlled.
Action:
Check the actuator. Change as necessary.
Check the cables for the actuator for breaks and
short circuits.
SID 24, Code 2.5.1 Control rod position sensor,
reference
Reason: Actuator not connected. Faulty value from
control rod position sensor in actuator.
Reaction: Engine is emergency stopped. Actuator
can not be controlled.
Action:
Check the actuator. Change as necessary.
Check the cables for the actuator for breaks and
short circuits.
115/209