Installation Manual

17
Configuration Options - Selection
SW01 Equipment Type
Range: HP2, AC2, HP1, AC1, hh1, hh2, HT, CL
HP2 operates a two--speed heat pump with a fan coil
HP1 operates a single--speed heat pump with a fan coil
AC2 operates a two--speed AC with a fan coil or furnace
AC1 operates a single--speed AC with a fan coil or furnace
Hh1 operates a single--speed heat pump with a furnace
Hh2 operates a two--speed heat pump with a furnace
HT operates a heat--only system. Furnace or fan coil only; no outdoor unit.
CL operates a cool only--system. Outdoor AC unit with an indoor fan coil with no strip
heaters.
Default is H2.
SW02 Clean Filter Timer
Select number of months before CHECK FILTER is displayed in the text box on the screen.
With OFF selected, the reminder will never come on, disabling this feature. Time selection can
range from 1 to 9 months by selecting numbers 1 through 9. For filter time recommendations,
please consult filter’s Installation Instruction for details.
SW03 Fahrenheit/Centigrade
Select between Fahrenheit (F) and Centigrade (C) operation.
Factory default is Fahrenheit (F).
SW04 Fan (G) On With W/W1
This selection determines whether fan (G) output is to be On or OFF when any W/W1 (furnace
or strip heat) output is On. Most furnaces and fan coils manage their own blowers and do not
require separate G signal. For these applications, select OFF. Some auxiliary heaters require
separate G signal to turn on blower. In this case, select On. Select On for geothermal
applications.
Default is OFF
SW05 Room Air Temperature Sensing (With Two-Wire Relay Module installed)
The remote room sensor may be installed as a single sensor or multiple sensors may be installed
for further averaging functionality. See Fig. 17.