Installation Manual

8
4.3. Location
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury
or death.
Disconnect power before routing control wiring.
!
WARNING
All wiring must comply with national, state, and local codes.
4.3.1. Wall Control
The Infinity System Control is the command center for the Infinity System. It
should b e located where it is easily accessible and visible to the adult homeowner
or end user. For accurate temperature measurement, the following guidelines should
be followed:
The Infinity System Control and Remote Room Sensors SHOULD be mounted:
S Approximately 5--ft (1 .5 m) from the floor.
S Close to or in a frequently used room, preferably on an inside partitioning wall.
S On a section of wall without pipes o r ductwork.
The Infinity System Control and Remote Room Sensors SHOULD NOT be
mounted:
S Close to a window, on an outside wall, or next to a door leading to the outside.
S Exposed to direct light or heat from a lamp, sun, fireplace, or other
temperature --radiatin g objects which could cause a false reading.