MS810 Laser Scanner Product Reference Guide Rev. A Copyright 2007 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
Preface About This Manual This manual explains how to install, operate and maintain the Unitech MS810 Laser Scanner. No part of this publication may be reproduced or used in any form, or by any electrical or mechanical means, without permission in writing from the manufacturer. This includes electronic or mechanical means, such as photocopying, recording, or information storage and retrieval systems. The material in this manual is subject to change without notice. © Copyright 2007 Unitech Electronics Co.
Table of Contents Preface About This Manual FCC Compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Chapter 1 Introduction Introducing the MS810. . . . . . . . . . . . . . . . . . . . . .
Chapter 1 Introduction A Tour of the MS810 The following section describes the main components and features of the MR810. 1 Introducing the MS810 2 The Unitech MS810 1D laser bar code scanner combines the best scanning performance and value. The device provides an accurate, easy, and fast method of data entry and data storage for computerized information systems. It is easy to install and does not require software or drivers to operate.
Laser Scan Engine Specifications Decode Zone Performance Light Source: The Decode Zone is based on Symbol’s Standard Code 39 PCS=0.9 lable in a 600 lux environment. 650 nm (+10/-5 nm) Laser Diode, 1mW (peak) Depth of Field (40 mils): Up to 420 mm Min. Scan Speed: 80 scans/sec Max Resolution: 0.
Chapter 2 Installation PS/2 (K/B) Cable Connection USB Cable Connection Insert the plug on the free end of the USB Communications Cable into any open USB port on the host as described below. Reset Configuration to Defaults If you are unsure of the scanner configuration or have scanned the incorrect codes, please scan the “Reset Configuration to Defaults” barcode. This will reset the scanner to its factory defaults settings in PS/2 interface.
Chapter 3 To Operate the MS810 Bar Code Setup Menu 1. Be sure that Host computer is turned OFF. 2. Ensure that all connections are secure. 3. Turn on your host computer and operate the scanner in Notepad, Word or your preferred software. 4. Aim the scanner at a barcode, ensure that the scanner is in trigger mode (default), and press the trigger. Multi-Interface Functions - 1 OUTPUT FIRMWARE VERSION RESET CONFIGURATION TO DEFAULTS 0A 0B 5. On successful decode, the blue LED light will turn on and off.
Multi-Interface Functions - 1 (cont.
Chapter 4 Interface - Keyboard Wedge WEDGE MODE - AUTODETECT PC Communication Bar Code Symbologies WEDGE MODE – SCAN SET 2 ` PASS THRU Introduction 000200 TRANSMIT SPEED - 0 000204 TRANSMIT SPEED TRANSMIT SPEED - 25 This section contains a list of supported symbologies with configurable settings for each symbology.
Symbologies On/Off - 2 CODE 93 - ENABLE Symbologies On/Off - 2 (cont.) CODE 93 00621 CODE 128 - ENABLE CODE 128 CODE 93 - DISABLE ID2OF5 - ENABLE 00620 01061 00690 CODE 128 ISBT - ENABLE CODE 128 ISBT - DISABLE 00701 00700 CODABAR 00851 I2OF5 - ENABLE ID2OF5 - DISABLE 01060 CODE 128 - DISABLE 00691 CODABAR - ENABLE INDUSTRIAL 2 OF 5 CODABAR - DISABLE 00850 INTERLEAVED 2 OF 5 00961 I2OF5 - DISABLE 00960 Copyright 2007 Unitech Electronics Co., Ltd. All rights reserved.
Symbologies On/Off - 3 MSI - ENABLE Symbologies Setup - 1 MSI MSI - DISABLE CODE 11 ID CHARACTER – “m” CODE 11 CODE 11 ID CHARACTER – “Z” 0131M 0131Z UPC-A DISABLE CODE 11 LASER/CCD REDUNDANCY - ENABLE CODE 11 LASER/CCD REDUNDANCY - DISABLE 00341 00340 01321 01320 UPC-E ENABLE UPC-E DISABLE CODE 39 SS CHAR - NONE 00351 00350 EAN-13 ENABLE EAN-13 DISABLE 00361 00360 EAN-8 ENABLE EAN-8 DISABLE 01151 UPC-A ENABLE 01150 UPC/EAN 00371 CODE 39 CODE 39 SS CHAR ‘+’ 002700 002704 CO
Symbologies Setup - 1 (cont.
Symbologies Setup - 2 (cont.
Symbologies Setup - 3 (cont.
Symbologies Setup - 4 (cont.
Symbologies Setup - 5 (cont.
Edit Setup Bar Codes Edit Setup Bar Codes (cont.
Macro/Special Keys Setup Bar Codes Termination String Setup Bar Codes MACRO #1 – FIND ‘1’ AND REPLACE WITH ‘ONE’ MACRO #1 - DISABLED STRING #1 – TERMINATION CHAR - CR STRING #1 – TERMINATION - LF 02010101011ONE 0B20101 0202011000$0D 0202011000$0A MACRO #2 – FIND ‘2’ AND REPLACE WITH ‘TWO’ FOR CODE 39 ONLY MACRO #2 - DISABLED STRING #1 – TERMINATION CR+LF STRING #1 - DISABLE 0201023012TWO 0B20102 0202011000$0D$0A 0B20201 MACRO – FIND ‘0’ AND REPLACE WITH ‘A’ MACRO – FIND ‘0’ AND REPLACE WI
Chapter 5 Termination String Setup Bar Codes (cont.
Chapter 6 Troubleshooting Problem: Nothing happens when I follow the operating instructions. Possible Cause: Possible Solution: Interface cables are loose Check for loose cable connections. If problem persits, call technical support for assistance. Problem: My computer gets a keyboard error while booting up. Possible Cause: Possible Solution: The scanner is damaged or is no longer functioning. Disconnect the scanner from your computer and use your keyboard only. Reboot your computer.
Problem: Scanned data is incorrectly displayed on the host. Possible Cause: Possible Solution: Scanner is not programmed to work with the host. Be sure proper host type is selected. For keyboard emulation configuration, ensure the system is programmed for the correct keyboard type, and that the CAPS LOCK key is off. Be sure editing options (e.g UPC-E to UPC-A Conversion) are properly programmed. The scanner’s Keyboard Country setting does not match the computer’s keyboard setup.