User manual
Copyright © 2011, Unitech America Inc. All rights reserved.
Page 53 of 61
MS246 User Manual
T17BStartID
61
Track 1, 7 Bit
Start Char
‘%’
‘%’ as track 1, 7 Bit Start
Sentinel
T16BStartID
62
T1, 6B Start
‘%’
‘%’ as track 1, 6 Bit Start
Sentinel
T15BStartID
63
T1, 5B Start
‘;’
‘;’ as track 1, 5 Bit Start
Sentinel
T27BStartID
64
Track 2, 7 Bit
Start Char
‘%’
‘;’ for Port
Powered IV
‘%’ as track 2, 7 Bit Start
Sentinel
T25BStartID
65
T2, 5BStart
‘;’
‘;’ as track 2, 5 Bit Start
Sentinel
T37BStartID
66
Track 3, 7 Bit
Start Char
‘%’
‘+’ for Port
Powered IV
‘%’ as track 3, 7 Bit Start
Sentinel
T36BStartID
67
T3, 6BStart
‘!’
‘+’ for Port
Powered IV
‘!’ as track 3, 6 Bit Start
Sentinel
T35BStartID
68
T3, 5BStart
‘;’
‘+’ for Port
Powered IV
‘;’ as track 3, 5 Bit Start
Sentinel
T1EndID
69
Track 1 End
Sentinel
‘?’
‘?’ as End Sentinel
T2EndID
6A
Track 2 End
Sentinel
'?'
‘?’ as End Sentinel
T3EndID
6B
Track 3 End
Sentinel
'?'
‘?’ as End Sentinel
T1ERRSTA
RTID
6C
Track 1 error
code
‘%’
Start sentinel if track 1
error report
T2ERRSTA
RTID
6D
Track 2 error
code
‘;’
Start sentinel if track 2
error report
T3ERRSTA
RTID
6E
Track 3 error
code
‘+’
Start sentinel if track 3
error report
T4ERRSTA
RTID*
6F
None
-
BootloaderID
*
70
Boot Loader
Mode
None
-
T344EndID*
71
None
T28BStartID
72
JIS T12
SS/ES
0
T38BStartID
73
JIS T3 SS/ES
0
EquipFwID
77
Feature option
setting
0-7
Reader firmware
configuration
n
r
BeepOffCom
ID*
7A
Turn off Beep
‘0’