User manual

Copyright © 2011, Unitech America Inc. All rights reserved.
Page 21 of 61
MS246 User Manual
7.9.11. Track Separator Selection
This option allows the user to select the character to be used to separate data
decoded by a multiple-track reader.
02 53 17 01 <Track_Separator> 03 LRC
<Track_Separator> is one ASCII Character.
The default value is C. 0h means no track separator.
7.9.12. Start/End Sentinel and Track 2 Account Number Only
The MS246 can be set to either send, or not send, the Start/End sentinel, and to
send either the Track 2 account number only, or all the encoded data on Track 2.
(The Track 2 account number setting doesn’t affect the output of Track 1 and
Track 3.)
02 53 19 01 <SendOption> 03 LRC
<SendOption>
‘0’ = Don’t send start/end sentinel and send all data on Track 2.
‘1’ = Send start/end sentinel and send all data on Track 2.
‘2’ = Don’t send start/end sentinel and send account number on Track 2.
‘3’ = Send start/end sentinel and send account number on Track 2.