User manual

Copyright © 2011, Unitech America Inc. All rights reserved.
Page 18 of 61
MS246 User Manual
Where:
<FuncID> is one byte identifying the setting(s) for the function.
<Len> is a one byte length count for the following function-setting block <FuncData>.
<FuncData> is the current setting for this function. It has the same format as in the
sending command for this function.
<FuncSETBLOCK> are in the order of their Function ID<FuncID>.
7.9 Set MSR Options Command
The default value is listed in bold.
7.9.1. Beep Volume
The beep volume and frequency can each be adjusted to two different levels, or
turned off.
02 53 11 01 <Beep Settings>03 LRC
Beep Settings:
‘0’ for beep volume off.
‘1’ for beep volume high, low frequency.
‘2’ for beep volume high, high frequency.
‘3’ for beep volume low, high frequency.
‘4’ for beep volume low, low frequency.
7.9.2. Change to Default Settings
02 53 18 03 LRC
This command does not have any <FuncData>. It returns all non-security settings
for all groups to their default values.
7.9.3. MSR Reading Settings
02 53 1A 01<MSR Reading Settings> 03 LRC
MSR Reading Settings:
‘0’ = MSR reading disabled.
‘1’ = MSR reading enabled.
7.9.4. Decoding Method Settings
02 53 1D 01<Decoding Method Settings> 03 LRC.
Decoding Method Settings:
‘0’ = raw data decoding in both directions.
‘1’ = decoding in both directions.
‘2’ = moving stripe along head in the direction of encoding.