- unitech Hand Held Scanner User's Manual
Page D.10
D.10 Data Editing:
 Enter Group 10  Group Default
0
1
2
3
4
5
6
7
8
9
+
-
 Review
 IN_ID
 LEN
 MATCH
 O-STR
 “
 *
 #
 Enter
 Backspace
 ,
Exit
Code Type:
 0 -- Code 39 Full  12 -- EAN 128
 1 -- Code 39 Std.  13 -- Code 32
 2 -- EAN-13  14 -- Delta Code
 3 -- UPC-A  15 – Label Code
 4 -- EAN-8  16 – Plessey Code
 5 -- UPC-E  17 -- Code 11(Special)
 6 -- I 2 of 5  18 – China Postal Code
 7 -- Codabar  19 – All Inputs
 8 -- Code 128
 9 -- Code 93
 10 -- S 2 of 5
 11 -- MSI Code
Formula Format:
 Input ID: IN_ID, ID1, ..., IDi,
 Length: LEN, MIN, MAX,
 Match: MATCH, P1,S1, ..., Pi, Si,
 A-String: “abc...”,
 O-String: O-STR, P, N,
 IDi -- number for Code ID.
 Pi -- position.
 Si -- string, “abc...”.
 P -- number or string for start position.
 N -- number of char. or string to end position.
Special Characters on this sheet:
 ,  -- delimiter to separate parameters.
 “ -- string specifier.
 * -- specify any digit or any position.
 # -- specify any letter or last position.