User's Manual
Table Of Contents
- About This Manual
- Regulatory Compliance Statements
- Laser Information
- LED Information
- Battery Notice
- Adapter Notice
- Hearing Damage Warning
- Worldwide Support
- North America
- Please scan QR Code to visit us :
- Warranty Policy
- 1.1 Package
- 1.2 Scanner Detail
- 1.3 Specifications
- 1.4 Getting Started
- 1.5 Battery Charging
- 1.6 LED Indicator / Beeper Sequence
- 1.7 Display Menu Tree
- 2.1 NFC Pairing with Mobile Devices
- 2.2 BT HID
- 2.3 BT SPP
- 2.4 BT SPP (Slave)
- 2.5 USB SPP
- 3.1 All symbologies
- 3.2 Message Length Description
- 3.3 1D
- 3.3.1 Codabar
- 3.3.2 Code 39
- 3.3.3 Interleaved 2 of 5
- 3.3.4 Code 93
- 3.3.5 Standard 2 of 5 Industrial (three-bar start/stop)
- 3.3.6 Standard 2 of 5 IATA (two-bar start/stop)
- 3.3.7 Matrix 2 of 5
- 3.3.8 Code 11
- 3.3.9 Code 128
- 3.3.10 UPC-A
- 3.3.11 UPC-E0
- 3.3.12 UPC-E1
- 3.3.13 EAN/JAN-13
- 3.3.14 EAN/JAN-8
- 3.3.15 MSI
- 3.3.16 GS1 DataBar Omnidirectional
- 3.3.17 GS1 DataBar Limited
- 3.3.18 GS1 DataBar Expanded
- 3.3.19 PDF 417
- 3.3.20 QR Code
- 3.3.21 Data Matrix
- 3.3.22 MaxiCode
- 3.3.23 Chinese Sensible (Han Xin) Code
- 3.4 2D
- 4.1 System setting
- 4.2 BT pairing
- 4.3 Output data transmit
- 4.4 BT Config
- 4.5 Beep & Vibration
- 4.6 Scan mode / Parameter Selection
- 4.7 Prefix/Suffix selections
- 4.8 Data formatting
- 4.9 Data Validation
- 4.10 Lookup Table Function
- 4.11 Manually set up
- 52 -
MS926 User’s Manual
3.3.15.1 MSI Check Character
Different types of check characters are used with MSI bar codes. You can
program the scanner to read MSI bar codes with Type 10 check characters.
Default = Validate Type 10, but Don’t Transmit. When Check Character is set
to Validate Type 10/11 and Transmit, the scanner will only read MSI bar codes
printed with the specified type check character(s), and will transmit the
character(s) at the end of the scanned data. When Check Character is set to
Validate Type 10/11, but Don’t Transmit, the unit will only read MSI bar codes
printed with the specified type check character(s), but will not transmit the
check character(s) with the scanned data.
Validate Type 10, but Don’t Transmit*
Validate Type 10 and Transmit
Validate 2 Type 10 Characters, but Don’t Transmit
Validate 2 Type 10 Characters and Transmit
Validate Type 11 then Type 10 Character, but Don’t Transmit
Validate Type 11 then Type 10 Character and Transmit
Disable MSI Check Characters