User's Manual
Table Of Contents
- About This Manual
- Regulatory Compliance Statements
- Laser Information
- LED Information
- Battery Notice
- Adapter Notice
- Hearing Damage Warning
- Worldwide Support
- North America
- Please scan QR Code to visit us :
- Warranty Policy
- 1.1 Package
- 1.2 Scanner Detail
- 1.3 Specifications
- 1.4 Getting Started
- 1.5 Battery Charging
- 1.6 LED Indicator / Beeper Sequence
- 1.7 Display Menu Tree
- 2.1 NFC Pairing with Mobile Devices
- 2.2 BT HID
- 2.3 BT SPP
- 2.4 BT SPP (Slave)
- 2.5 USB SPP
- 3.1 All symbologies
- 3.2 Message Length Description
- 3.3 1D
- 3.3.1 Codabar
- 3.3.2 Code 39
- 3.3.3 Interleaved 2 of 5
- 3.3.4 Code 93
- 3.3.5 Standard 2 of 5 Industrial (three-bar start/stop)
- 3.3.6 Standard 2 of 5 IATA (two-bar start/stop)
- 3.3.7 Matrix 2 of 5
- 3.3.8 Code 11
- 3.3.9 Code 128
- 3.3.10 UPC-A
- 3.3.11 UPC-E0
- 3.3.12 UPC-E1
- 3.3.13 EAN/JAN-13
- 3.3.14 EAN/JAN-8
- 3.3.15 MSI
- 3.3.16 GS1 DataBar Omnidirectional
- 3.3.17 GS1 DataBar Limited
- 3.3.18 GS1 DataBar Expanded
- 3.3.19 PDF 417
- 3.3.20 QR Code
- 3.3.21 Data Matrix
- 3.3.22 MaxiCode
- 3.3.23 Chinese Sensible (Han Xin) Code
- 3.4 2D
- 4.1 System setting
- 4.2 BT pairing
- 4.3 Output data transmit
- 4.4 BT Config
- 4.5 Beep & Vibration
- 4.6 Scan mode / Parameter Selection
- 4.7 Prefix/Suffix selections
- 4.8 Data formatting
- 4.9 Data Validation
- 4.10 Lookup Table Function
- 4.11 Manually set up
- 107 -
MS926 User’s Manual
■ Search backward for a non-matching character
E7 Search the input message backward for the first non-“xx” character from
the current cursor position, leaving the cursor pointing to the non-“xx”
character. Syntax = E7xx where xx stands for the search character’s hex
value for its ASCII code. Refer to the ASCII Conversion Chart (Code
Page 1252), for decimal, hex and character codes.
4.8.4.4 Miscellaneous Commands
■ Suppress characters
FB Suppress all occurrences of up to 15 different characters, starting at the
current cursor position, as the cursor is advanced by other commands.
When the FC command is encountered, the suppress function is
terminated. The cursor is not moved by the FB command. Syntax =
FBnnxxyy . .zz where nn is a count of the number of suppressed
characters in the list, and xxyy .. zz is the list of characters to be
suppressed.
FB Example: Remove spaces in bar code data
This example shows a bar code that has spaces in the data. You may want to
remove the spaces before sending the data. Using the bar code above:
Command string: FB0120F10D
FB is the “Suppress characters” command
01 is the number of character types to be suppressed
20 is the hex value for a space
F1 is the “Send all characters” command
0D is the hex value for a CR
The data is output as:
34567890
<CR>