7
Compose start character
Scanning / Triggering - Software Trigger - stop character [ETX] (03h) (*)
<SW>704403
Turn off after good read
- When active, the scan engine stops the reading session after a successful
decoding.
- Turn off after good read is only used in the following trigger modes:
- Level
- Pulse
- Autostand
- Standard Aim
- NOTE: this parameter is NOT used with continuous and flashing modes.
Scanning / Triggering - Turn off after good read - Enable (*)
<SW>704601
Scanning / Triggering - Turn off after good read - Disable
<SW>704600
Retrigger delay
- Only valid if "Turn off after good read" is disabled.
- This setting is a time delay in which the scanner turns off after a good read.
When the delay is done, the scanner automatically turns back on (retriggers).