User's Manual

5
Scanning / Triggering - Trigger timeout (sec) - 2 (*)
<SW>70800002
Trigger activation
- Used to enable or disable hardware or emulated triggers.
- IMPORTANT: You cannot activate the trigger line if the hardware trigger is
disabled. If you are using level or pulse trigger modes, the only way to
re-activate the hardware trigger is by using online set up (ISCP terminal) or
sending an ISCP command.
Hardware and emulated triggers are disabled. The only way to turn the imager
on is by sending a decode on/decode off control command (20, 40).
Scanning / Triggering - Trigger activation - Disabled
<SW>704100
Hardware trigger ONLY is enabled.
Scanning / Triggering - Trigger activation - Hardware trigger enabled
<SW>704101
Emulated trigger ONLY is enabled.
- The trigger can only be activated by sending the emulated trigger ISCP
control command 50, 47.
Scanning / Triggering - Trigger activation - Emulated trigger enabled
<SW>704102