Wireless Pocket 2D Imager Scanner - MS920 - User Manual
Table of Contents 1. Package Contents ......................................................................................1 2. Scanner Detail ............................................................................................1 3. Getting Started ...........................................................................................2 4. Specifications.............................................................................................5 5. Configuration Barcode .........................
Inter- message delay .......................................................................15 Data editing .....................................................................................16 Activate scenarios ....................................................................17 Symbologies .............................................................................................20 Disable all symbologies ...................................................................20 Australian Post ........
Concatenation mode .........................................................31 Codablock........................................................................................32 Codablock A .............................................................................32 Symbology identifier ..........................................................32 User defined...............................................................32 code mark ..................................................................
Barcode length .........................................................................45 Length mode .....................................................................45 Code 128 / GS1-128........................................................................46 Symbology identifier .................................................................46 User defined ......................................................................46 Code 128.............................................................
UPC-E ........................................................................59 EAN-8 ........................................................................60 EAN-13.......................................................................60 Code mark.........................................................................60 UPC-A ........................................................................60 UPC-E ........................................................................60 EAN-8 .................
Unconventional.........................................................................71 GS1 DataBar (RSS).........................................................................72 Omni-directional .......................................................................72 Symbology identifier .................................................................72 User defined ......................................................................72 Code mark......................................................
Matrix 2 of 5.....................................................................................82 Symbology identifier .................................................................83 User defined ......................................................................83 Code mark.........................................................................83 Matrix stop/start char ................................................................83 Set length L1, L2 and L3 ....................................
Incomplete decode event .........................................................93 PDF417 ...........................................................................................93 •Symbology identifier................................................................94 User defined ......................................................................94 Code mark.........................................................................94 Structured append ..................................................
Code mark.......................................................................105 Format ....................................................................................106 Check digit..............................................................................106 Check digit verification ....................................................106 Check digit transmission .................................................107 Barcode length ..................................................................
Ignore stand detect...................................................................10 Double scan prevention............................................................10 Data decoding security ............................................................................ 11 Predefined security levels................................................................ 11 Consecutive same read data validation ...........................................12 Timeout between different consecutive codes (ms).........
1. Package Contents Please make sure the following contents are in the MS920 carton. If something is missing or damaged, please contact your Unitech representative. MS912 scanner Resource CD Quick Guide Hand Strap Battery USB Charging Cable Note: 1. The scanner’s default power off (idle mode) time is 3 minutes. 2. Please charge scanner for at least 2 hours prior to initial use. 2.
3. Getting Started To scan a barcode, make sure the aiming beam crosses every bar and space of the barcode. BATTERY CHARGING 1. Flip up the rubber cover to expose the mini USB port on the scanner. 2. Insert the mini USB connector into the port on the scanner and the standard USB connector of the USB cable into a USB port on the host PC. Pairing With PC/Notebook For The First Time PC (HID mode) Following steps are based on Microsoft Windows 7. 1. Use MS920 to scan barcode “HID”. , and then, on 2.
are listed on the reverse side of this sheet. PC (SPP mode) Following steps are based on Microsoft Windows 7. 1. Use MS920 t0 scan barcode “SPP”. 2. Open Devices and Printers by clicking the Start button , and then, on the Start menu, clicking Devices and Printers. 3. Click Add a device, and then click the Unitech BT XXXXXX icon. 4.
Buffer Erasing Under Inventory Mode 1. Scan (Erase Inventory Buffer) Under Batch Mode 1. Scan (Erase Batch Buffer) . 2. Scan (Erase) 2. Scan (Erase) For detail information about barcodes, please refers to section 5. Appendix Bar Code Configuration And Commands. 4 .
4. Specifications Specifications Light source Illumination: Highly visible white LED Aiming : 617 nm red LED Scan rate Sensor 240 scans/sec Resolution PCS Housing Profile Working Hours Charge Time Coverage Operating Temp Symbologies Linear CMOS sensor 1D codes 0.1 mm (4 mils) 2D codes 0.167 mm (6.
5. Configuration Barcode Resets all parameters - Resets all configuration parameters to their default values except for locked parameters. Reset factory defaults 4006 Interface Keyboard settings - Keyboard settings only apply when using a the following interfaces: - USB Keyboard HID - Keyboard Wedge - HID Keyboard Bluetooth device profile Selection - Select the keyboard for your application.
Keyboard settings - Selection - German Windows 674002 Keyboard settings - Selection - French Canadian Windows 95/98 674003 Keyboard settings - Selection - French Canadian Windows XP/2000 674004 Keyboard settings - Selection - Spanish Windows 674005 Keyboard settings - Selection - Italian Windows 674006 Keyboard settings - Selection - Swedish Windows 674007 2
Keyboard settings - Selection - UK English Windows 674008 Keyboard settings - Selection - Japanese Windows 674009 Keyboard settings - Selection - Brazilian Portuguese Windows 67400A Keyboard settings - Selection - IBM / NCR Terminals 67400B Keyboard settings - Selection - Czech QWERTY 67400C Keyboard settings - Selection - Slovakian QWERTY 67400D 3
Keyboard settings - Selection - Hungarian 101-key 67400E Keyboard settings - Selection - Swiss German 67400F Keyboard settings - Selection - Swiss French 674010 Keyboard settings - Selection - Danish 674011 Keyboard settings - Selection - Norwegian 674012 Keyboard settings - Selection - Hungarian 674013 4
Keyboard settings - Selection - Norwegian 674012 Keyboard settings - Selection - Dutch 674014 Keyboard settings - Selection - Portuguese 674015 Keyboard settings - Selection - Belgian French 674016 Extended ASCLL - Keyboard settings only apply when using a the following interfaces: - USB Keyboard HID - Keyboard Wedge - HID Keyboard Bluetooth device profile Keyboard settings - Extended ASCII - Send codes w/chars mapped to Windows-1252 (*) 674201 5
Keyboard settings - Extended ASCII - Send codes w/chars ignored 674202 Keyboard settings - Extended ASCII - Do not send codes w/ext ASCII chars 674203 Special keys transmission - Only for use with a USB or keyboard wedge cable. - Only symbologies that support the full ASCII character set allow the encoding of special keyboard keys such as [Return] and [Tab]. - No symbologies support the encoding of other functions keys such as [PF1] and [PageDown].
Keyboard settings - Special keys transmission - Alt mode - Enable 674301 CAPS / NUM lock state - Only applies to Keyboard wedge (PS2) interface. - Use this setting to set the CAPS / NUM lock state. - The autodetect option allows the scanner to automatically detect the state of the CAPS and NUM lock.
Keyboard settings - CAPS / NUM state - CAPS and NUM = ON 674504 Data Transmission Settings - Modify data transmission settings to optimize performance. ISCP - Intermec Scanner Control Protocol parameters ISCP - ISCP (*) 614001 Sending this parameter during online setup will lose the connection (click "Connect" to reestablish the connection). ISCP - None 614000 Data format - Barcode data is sent without a frame and no acknowledgement is necessary.
Extended barcode data format - "Packet" data format must be activated to enable BCD transmission. - Precedes barcode data with "[BCD]" indicator. ISCP - Data format - Extended barcode data format - BCD 734E00 - "Packet" data format must be activated to enable BCDEX transmission. - Precedes barcode data with "[BCDEX]" indicator and extended information: [BCDEX2]01 0001 0000 0000 000D 0002 0005 (+ barcode data etc.
ISCP bar code - When active the scanner informs the host of the following information after reading and processing an ISCP bar code: - Error (if any) - Type of ISCP bar code (setup, status, etc.) - GID - FID - Parameter - For information on the event frame received by the host see the ISCP online help available in the help menu in Easyset.
ISCP - Event notification - Preprocessing ISCP bar code - Enable 734401 Unsuccessful decoding - This event is sent whenever a decode session is deactivated (trigger released) and no decode has taken place.
ISCP - Event notification - End of read session - Enable 734801 Start-up ISCP - Event notification - Start-up - Disable (*) 734900 ISCP - Event notification - Start-up - Enable 734901 Trigger pulled ISCP - Event notification - Trigger pulled - Disable (*) 734A00 ISCP - Event notification - Trigger pulled - Enable 734A01 Trigger released ISCP - Event notification - Trigger released - Disable (*) 734B00 ISCP - Event notification - Trigger released - Enable 734B01 12
Wake-up ISCP - Event notification - Wake-up - Disable (*) 734500 ISCP - Event notification - Wake-up - Enable 734501 ISCP - Event notification - Structured append - Disable (*) 735000 ISCP - Event notification - Structured append - Enable 735001 Symbology identifier Symbology identifier - Not transmitted (*) 604000 Symbology identifier - AIM format 604002 13
Symbology identifier - User Defined Identifier 604003 Symbology identifier - Code mark 604001 Preamble Preamble - None (*) 60C00000 Postamble Postamble - Carriage Return + Line Feed (*) 60C100020D0A Postamble - None 60C10000 Inter-character/message delay Avoids dropping characters if transmitting decoded data too fast for the host system Inter-character delay Inter-character/message delay - Inter-character delay - 0 (*) 60800000 14
Inter-character/message delay - Inter-character delay - 10 6080000A Inter-character/message delay - Inter-character delay - 20 60800014 Inter-character/message delay - Inter-character delay - 30 6080001E Inter-character/message delay - Inter-character delay - 40 60800028 Inter-character/message delay - Inter-character delay - 50 60800032 Inter- message delay - Value is in milliseconds.
Inter-character/message delay - Inter-message delay - 10 6081000A Inter-character/message delay - Inter-message delay - 30 6081001E Inter-character/message delay - Inter-message delay - 50 60810032 Inter-character/message delay - Inter-message delay - 80 60810050 Inter-character/message delay - Inter-message delay - 100 60810064 Data editing - IMPORTANT [[[[ The data editing function is only available with STCDecode version 1.1.5.
- The order in which you define the scenarios is important (the product compares incoming data with each scenario in turn and edits the data for the first matching scenario it finds). 1. Activate the scenario(s) you want the product to detect. 2. Define the input data you want to intercept for editing (any combination of input type, input length, input mask). 3.
Data editing - Scenario 2 - Enable 654101 Scenario 3 Data editing - Scenario 3 - Disable (*) 654200 Data editing - Scenario 3 - Enable 654201 Scenario 4 Data editing - Scenario 4 - Disable (*) 654300 Data editing - Scenario 4 - Enable 654301 Scenario 5 Data editing - Scenario 5 - Disable (*) 654400 18
Data editing - Scenario 5 - Enable 654401 Scenario 6 Data editing - Scenario 6 - Disable (*) 654500 Data editing - Scenario 6 - Enable 654501 Scenario 7 Data editing - Scenario 7 - Disable (*) 654600 Data editing - Scenario 7 - Enable 654601 19
Symbologies Disable all symbologies Disable all symbologies 4003 Australian Post - 4-State postal barcode - Only available with models equipped with an area imager. Australian Post - Disable (*) 344000 Australian Post - Enable 344001 Symbology identifier User defined Australian Post - Symbology identifier - User defined - P3 (*) 34C000025033 Code mark - See "Data transmission settings - symbology identifier - code mark" to activate or deactivate code mark transmission.
Australian Post - Symbology identifier - Code mark - * (*) 34482A Aztec - Two-dimensional matrix style symbology. - Can encode around 3000 characters using entire 256-byte ASCII. - Only available with models equipped with an area imager.
GS1-128 emulation Aztec - GS1-128 emulation - Disable (*) 534300 Aztec - GS1-128 emulation - Enable 534301 Structured append Aztec - Structured append - Disable (*) 534100 Aztec - Structured append - Enable 534101 Header transmission Aztec - Structured append - Header transmission - Disable (*) 534600 Aztec - Structured append - Header transmission - Enable 534601 22
Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters). Aztec - Symbology identifier - User defined - D3 (*) 53C000024433 Code mark - See "Data transmission settings - symbology identifier - code mark" to activate or deactivate code mark transmission.
BPO - Enable 324001 Symbology identifier UDSI - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters). - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission.
BPO - Symbology identifier - code mark - * (*) 32482A check digit transmission BPO - check digit transmission - Enable (*) 325401 BPO - check digit transmission - Disable 325400 Canada Post - 4-state symbology Canada Post - Disable (*) 334000 Canada Post - Enable 334001 25
Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters).
Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters). Codabar - Symbology identifier - User defined - B7 (*) 40C000024237 code mark - See "Data transmission settings - symbology identifier - code mark" to activate or deactivate code mark transmission.
Codabar - Start/Stop - A, B, C, D 405802 Codabar - Start/Stop - a, b, c, d / t, n, *, e 405803 Codabar - Start/Stop - DC1, DC2, DC3, DC4 405804 CLSI library system - Spaces inserted after characters 1, 5, 10 in the 14-character label (used in the USA by libraries using the CLSI system). Example: "39990000192148" is transmitted as "3 9990 00019 2148" -Start/stop can be transmitted or not transmitted as required.
Check digit Check digit verification Codabar - Check digit - check digit verification - Disable (*) 404C00 Codabar - Check digit - check digit verification - Enable 404C01 Check digit transmission - You can chose to transmit or not transmitted the check digit.
- Minimum length possible = 3 characters. - If the codes in your application have fixed lengths, use barcode length mode "L1, L2, and L3 as fixed lengths. Codabar - Barcode length - Length mode - L1 as Minimal length (*) 405300 Codabar - Barcode length - Length mode - L1, L2, L3 as fixed length 405301 Codabar - Barcode length - Length mode - L1 as min, L2 as max 405302 Set length L1, L2 and L3 - Set barcode length L1, L2 and L3 according to the barcode length mode used.
Codabar - Concatenation - Disable (*) 405A00 Codabar - Concatenation - Transmit concatenated codes or single codes 405A02 Codabar - Concatenation - Only transmit concatenated codes 405A01 Concatenation mode - Applies concatenation according to the desired start / stop configuration.
Codablock Codablock A Codablock - Codablock A - Disable (*) 4D4000 Codablock - Codablock A - Enable 4D4001 Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters).
Codablock - Codablock A - Symbology identifier - Code mark - * (*) 4D482A Codablock F Codablock - Codablock F - Disable (*) 4D4100 Codablock - Codablock F - Enable 4D4101 Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters).
Code 11 Code 11 - Disable (*) 4A4000 Code 11 - Enable 4A4001 Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters).
Check digits Code 11 - Check digits - 1 digit (*) 4A4C01 Code 11 - Check digits - 2 digits 4A4C02 Code 11 - Check digits - Transmitted (*) 4A5401 Code 11 - Check digits - Not transmitted 4A5400 Barcode length - Use the L1 as minimum length option if you know the minimum length of the codes in your application!!! - To optimize decoding performance and increase security, select the same length as the minimum length in your application (do not select a shorter length!!).
- L3 = Codes at least the length specified by L1 and no longer than the maximum length specified by L2 are read (L3 is not used). Code 11 - Barcode length - Length mode - L1 as Minimal length (*) 4A5300 Code 11 - Barcode length - Length mode - L1, L2, L3 as fixed length 4A5301 Code 11 - Barcode length - Length mode - L1 as min, L2 as max 4A5302 Set length L1, L2 and L3 - Set barcode length L1, L2 and L3 according to the barcode length mode used. Code 39 - Alphanumeric symbology.
Code 39 - Enable (*) 424001 Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters).
Code 39 - Format - Full ASCII (extended) 425A01 Start/Stop Code 39 - Start/Stop - Not transmitted (*) 425800 Code 39 - Start/Stop - Transmitted 425801 accepted characters Code 39 - Start/Stop - accepted characters - '*' only (*) 425902 Code 39 - Start/Stop - accepted characters - '$' only 425901 Code 39 - Start/Stop - accepted characters - '$' and '*' 425903 38
Check digit check digit verification Code 39 - Check digit - check digit verification - Disable (*) 424C00 Code 39 - Check digit - check digit verification - Modulo 43 424C01 Code 39 - Check digit - check digit verification - French CIP 424C02 Code 39 - Check digit - check digit verification - Italian CPI 424C03 check digit transmission You can chose to transmit or not transmitted the check digit.
Code 39 - Check digit - check digit transmission - Enable 425401 Barcode length Length mode - L1 = Codes with as many characters as specified by L1 and longer are read (L2 and L3 are not used). - L2 = Only codes that comply with the lengths specified by L1, L2, and L3 will be read. - L3 = Codes at least the length specified by L1 and no longer than the maximum length specified by L2 are read (L3 is not used).
Code 39 - Reading range - Extended (*) 424701 Code 39 - Reading range - Normal 424700 Reading tolerance - Sets the tolerance level for reading hard to read bar codes. - High = most permissive (reads codes of variable quality). - Low = least permissive (only reads high quality codes that meet official Code 39 standards) - Quiet zone verification (space before and after bar code to ensure correct decoding).
Unconventional Code 39 - Used for decoding unconventional Code 39 such as: - very large inter-character - large ratio between narrow and wide elements Code 39 - Unconventional Code 39 - Disable (*) 424300 Code 39 - Unconventional Code 39 - Enable 424301 Special keys interpretation - Special keyboard keys such as [Enter] and [Tab] (see list below) can be interpreted and transmitted by using dual-character combinations. - This function is also compatible with the Code 39 full ASCII format.
TAB .I PF9 0I ALT .J PF10 0J BACK TAB .K PF11 BACKSPACE .L PF12 right arrow .M PF13 left arrow .N PF14 up arrow .O PF15 0O down arrow .P PF16 CLEAR .Q PF17 0Q FIELD - .R PF18 0R DUP .S PF19 ESC .T PF20 LINE FEED .U PF21 RESET .V PF22 0V CTRL .W PF23 0W SHIFT .X PF24 0K 0L 0M 0N 0P 0S 0T 0U 0X Code 39 - Special keys interpretation - Disable (*) 425F00 Code 39 - Special keys interpretation - Enable 425F01 Code 93 / Code 93i - Code 93 Alphanumeric full ASCII symbology - letter case defined.
Code 93 / Code 93i - Disable (*) 414000 Code 93 / Code 93i - Enable 414001 Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters).
Barcode length - Use the L1 as minimum length option if you know the minimum length of the codes in your application!!! - To optimize decoding performance and increase security, select the same length as the minimum length in your application (do not select a shorter length!!). Length = [barcode data] - Minimum length possible = 1 character. Length mode - L1 = Codes with as many characters as specified by L1 and longer are read (L2 and L3 are not used).
Code 128 / GS1-128 - Alphanumeric full ASCII symbology - letter case defined. - "GS1-128" = Code 128 with the FNC1 character in the first position Code 128 / GS1-128 - Code 128 enable (*) 434001 Code 128 / GS1-128 - Code 128 disable 434000 Code 128 / GS1-128 - GS1-128 enable (*) 434201 Code 128 / GS1-128 - GS1-128 disable 434200 Symbology identifier User defined - User defined symbology identifier.
Code 128 Code 128 / GS1-128 - Symbology identifier - User defined - Code 128 - B3 (*) 43C000024233 GS1-128 Code 128 / GS1-128 - Symbology identifier - User defined - GS1-128 - C9 (*) 43C100024339 Code mark - See "Data transmission settings - symbology identifier - code mark" to activate or deactivate code mark transmission. - Use the default value or compose your code mark for this symbology (1 character).
Code 128 / GS1-128 - GS1-128 identifier - Enable (*) 435801 Code 128 / GS1-128 - GS1-128 identifier - Disable 435800 CIP 128 French pharmaceutical codes - Embedded CIP 39 data. - Fixed length of 14 characters. - Code 128 character set C Code 128 / GS1-128 - CIP 128 French pharmaceutical codes - Disable (*) 434C00 Code 128 / GS1-128 - CIP 128 French pharmaceutical codes - French CIP 434C01 FNC1 separator character (GS1-128 norms) - Default = GS function character (ASCII 29).
Code 128 / GS1-128 - FNC1 separator character (GS1-128 norms) - (*) 43591D Barcode length - Use the L1 as minimum length option if you know the minimum length of the codes in your application!!! - To optimize decoding performance and increase security, select the same length as the minimum length in your application (do not select a shorter length!!). Length = [barcode data] - Minimum length possible = 1 character.
Code 128 / GS1-128 - Barcode length - Length mode - L1 as min, L2 as max 435302 Reading tolerance - Sets the tolerance level for reading hard to read bar codes. - High = most permissive (reads codes of variable quality).
- Codes are not concatenated by default (default transmission setting is "single codes only"). - You must select one of the "concatenated codes" transmission options to send concatenated codes (see "transmit" section). Code 128 / GS1-128 - ISBT 128 - Disable (*) 434100 Code 128 / GS1-128 - ISBT 128 - active 434101434000434200 transmit - IMPORTANT: - Codes are not concatenated by default (default transmission setting is "single codes only").
Code 128 / GS1-128 - ISBT 128 - transmit - Transmit concatenated codes or single codes 435A02 concatenate - IMPORTANT: - Codes are not concatenated by default (default transmission setting is "single codes only"). - You must select one of the "concatenated codes" transmission options to send concatenated codes (see "transmit" section).
Code 128 / GS1-128 - GTIN processing - Disable (*) 436000 Code 128 / GS1-128 - GTIN processing - Enable 436001 Unconventional GS1-128 - You can activate the 3 options separately or use them together. - Unconventional GS1-128 = Can decode unconventional GS1-128 (GS1-128 with 2 FNC1 chars) - FNC2 append disabled = instructs the scanner to store data from the bar code containing the FNC2 and trnsmit it as a prefix to the date of the next bar code.
DataMatrix - Two-dimensional symbology. - Only available with models equipped with an area imager. - Can encode up to approximately 2 000 characters. - Negative image DataMatrix supported. - Mirror image DataMatrix not supported. DataMatrix - Enable (*) 544001 DataMatrix - Disable 544000 Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission.
DataMatrix - Symbology identifier - Code mark - * (*) 54482A Mirrored labels activation - When enabled mirrored labels can be read as well as normal labels. - When disabled only normal labels can be read.
Header transmission DataMatrix - Structured append - Header transmission - Disable (*) 544600 DataMatrix - Structured append - Header transmission - Enable 544601 Dutch Post - 4-State postal barcode. - Only available with models equipped with an area imager. Dutch Post - Disable (*) 364000 Dutch Post - Enable 364001 Symbology identifier User defined - User defined symbology identifier.
Dutch Post - Symbology identifier - User defined - P4 (*) 36C000025034 Code mark Dutch Post - Symbology identifier - Code mark - * (*) 36482A EAN/UPC Numerical symbology.
EAN/UPC - UPC-E disable 4B4100 EAN/UPC - EAN-8 enable (*) 4B4201 EAN/UPC - EAN-8 disable 4B4200 EAN/UPC - EAN-13 enable (*) 4B4301 EAN/UPC - EAN-13 disable 4B4300 UPC-E1 - Irregular UPC-E with number system equal to 1 (usually the first printed character). - UPC-E must be active for UPC-E1 to be taken into account.
EAN/UPC - UPC-E1 - Enable 4B4C01 EAN/UPC - UPC-E1 - Disable (*) 4B4C00 Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters).
EAN-8 EAN/UPC - Symbology identifier - User defined - EAN-8 - FF (*) 4BC200024646 EAN-13 EAN/UPC - Symbology identifier - User defined - EAN-13 - F (*) 4BC3000146 Code mark UPC-A EAN/UPC - Symbology identifier - Code mark - UPC-A - A (*) 4B4841 UPC-E EAN/UPC - Symbology identifier - Code mark - UPC-E - E (*) 4B4945 EAN-8 EAN/UPC - Symbology identifier - Code mark - EAN-8 - N (*) 4B4A4E 60
EAN-13 EAN/UPC - Symbology identifier - Code mark - EAN-13 - F (*) 4B4B46 Add-on digits EAN/UPC - Add-on digits - not required but transmitted if read (*) 4B5D00 EAN/UPC - Add-on digits - required and transmitted 4B5D01 add-on 2 EAN/UPC - Add-on digits - add-on 2 - Disable (*) 4B4500 EAN/UPC - Add-on digits - add-on 2 - Enable 4B4501 61
add-on 5 EAN/UPC - Add-on digits - add-on 5 - Disable (*) 4B4600 EAN/UPC - Add-on digits - add-on 5 - Enable 4B4601 security level - Used with "add-on not required but transmitted if read" option. - Defines security level for add-on 2 and add-on 5 (range 0 to 100). - Higher security level = lower decode rate.
EAN/UPC - Check digit transmission - UPC-A - Disable 4B5400 UPC-E EAN/UPC - Check digit transmission - UPC-E - Enable (*) 4B5501 EAN/UPC - Check digit transmission - UPC-E - Disable 4B5500 EAN-8 EAN/UPC - Check digit transmission - EAN-8 - Enable (*) 4B5601 EAN/UPC - Check digit transmission - EAN-8 - Disable 4B5600 EAN-13 EAN/UPC - Check digit transmission - EAN-13 - Enable (*) 4B5701 63
EAN/UPC - Check digit transmission - EAN-13 - Disable 4B5700 UPC number system UPC-A EAN/UPC - UPC number system - UPC-A - Enable (*) 4B5801 EAN/UPC - UPC number system - UPC-A - Disable 4B5800 UPC-E EAN/UPC - UPC number system - UPC-E - Enable (*) 4B5901 EAN/UPC - UPC number system - UPC-E - Disable 4B5900 64
Re-encoding UPC-A, UPC-E, EAN-8 [leading character] [number system] [data] [check digit] - Converts decoded data to other code formats. - Transmission only takes into account the parameters available for the target bar code format. - Regular UPC-A has a transmitted number system equal to 0. - To transmit the additional leading character (country code), select the "UPC-A transmitted as EAN-13" option.
EAN/UPC - Re-encoding UPC-A, UPC-E, EAN-8 - EAN-8 transmitted as EAN-8 (*) 4B5C00 EAN/UPC - Re-encoding UPC-A, UPC-E, EAN-8 - EAN-8 transmitted as EAN-13 4B5C01 ISBN - International Standard Book Number - EAN-13 code, the first 3 characters "978" or "979" (except for "9790") are ignored and the checksum (0..9, "X") is calculated on the remaining characters.
EAN/UPC - ISMN - Disable (*) 4B6100 EAN/UPC - ISMN - Enable 4B6101 ISSN - International Standard Serial Number - EAN-13 code, the first 3 characters "977" are ignored and the ISBN checksum (0..9, "X") is calculated on the remaining characters. EAN/UPC - ISSN - Disable (*) 4B6200 EAN/UPC - ISSN - Enable 4B6201 GTIN processing - GTIN = Global Trade Item Number. - GTIN processing transmits EAN/UPC as the 14 character GS1 Composite GTIN.
EAN/UPC - GTIN processing - Disable (*) 4B6000 EAN/UPC - GTIN processing - Enable 4B6001 Reading range - Applies a special algorithm for long-distance reading (default setting). - Use the "normal" setting if distance reading is not required.
GS1 Composite - CC-A/B - Enable 564001 CC-C GS1 Composite - CC-C - Disable (*) 564100 GS1 Composite - CC-C - Enable 564101 EAN/UPC composite message decoding - Only applied to composite codes based on EAN/UPC.
GS1 Composite - EAN/UPC composite message decoding - Never linked 565E00 Symbology identifier User defined CC-A/B GS1 Composite - Symbology identifier - User defined - CC-A/B - G0 (*) 56C000024730 CC-C GS1 Composite - Symbology identifier - User defined - CC-C - G1 (*) 56C100024731 Code mark - See "Data transmission settings - symbology identifier - code mark" to activate or deactivate code mark transmission.
CC-C GS1 Composite - Symbology identifier - Code mark - CC-C - * (*) 56492A Linear transmission only - Applied to all composite codes. - Allows you to decide to only transmit the linear code. GS1 Composite - Linear transmission only - Disable (*) 564400 GS1 Composite - Linear transmission only - Enable 564401 Unconventional When enabled the AIM identifier is always removed.
GS1 DataBar (RSS) Omni-directional - Numerical symbology. - Reads the following types of GS1 DataBar: GS1 DataBar Omni-Directional GS1 DataBar Truncated GS1 DataBar Stacked GS1 DataBar Stacked Omni-Directional GS1 DataBar (RSS) - Omni-directional - Enable 4F4001 GS1 DataBar (RSS) - Omni-directional - Disable (*) 4F4000 Symbology identifier User defined - User defined symbology identifier.
Code mark GS1 DataBar (RSS) - Omni-directional - Symbology identifier - Code mark - * (*) 4F482A Limited GS1 DataBar (RSS) - Limited - Enable 4F4101 GS1 DataBar (RSS) - Limited - Disable (*) 4F4100 Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters).
Code mark GS1 DataBar (RSS) - Limited - Symbology identifier - Code mark - * (*) 4F492A Expanded GS1 DataBar (RSS) - Expanded - Enable 4F4201 GS1 DataBar (RSS) - Expanded - Disable (*) 4F4200 Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters).
Code mark - See "Data transmission settings - symbology identifier - code mark" to activate or deactivate code mark transmission. - Use the default value or compose your code mark for this symbology (1 character). GS1 DataBar (RSS) - Expanded - Symbology identifier - Code mark - * (*) 4F4A2A Infomail Infomail - Disable (*) 394000 Infomail - Enable 394001 Symbology identifier User defined - User defined symbology identifier.
Code mark - See "Data transmission settings - symbology identifier - Code mark" to activate or deactivate Code mark transmission. - Use the default value or compose your Code mark for this symbology (1 character). Infomail - Symbology identifier - Code mark - * (*) 39482A Intelligent mail Intelligent mail - Disable (*) 3A4000 Intelligent mail - Enable 3A4001 Symbology identifier User defined - User defined symbology identifier.
Code mark - See "Data transmission settings - symbology identifier - Code mark" to activate or deactivate Code mark transmission. - Use the default value or compose your Code mark for this symbology (1 character). Intelligent mail - Symbology identifier - Code mark - * (*) 3A482A Interleaved 2 of 5 - Numerical symbology. - For GTIN compatibility set barcode length to one fixed length of 14 characters.
Code mark - See "Data transmission settings - symbology identifier - Code mark" to activate or deactivate Code mark transmission. - Use the default value or compose your Code mark for this symbology (1 character). Interleaved 2 of 5 - Symbology identifier - Code mark - I (*) 444849 Check digit - Especially recommended for variable length Interleaved 2 of 5 and if "consecutive same read data validation" (data decoding security parameters) is not activated.
Check digit transmission Interleaved 2 of 5 - Check digit - Check digit transmission - Disable (*) 445400 Interleaved 2 of 5 - Check digit - Check digit transmission - Enable 445401 Barcode length Use the L1 as minimum length option if you know the minimum length of the codes in your application!!! - To optimize decoding performance and increase security, select the same length as the minimum length in your application (do not select a shorter length!!).
- L2 = Only codes that comply with the lengths specified by L1, L2, and L3 will be read. - L3 = Codes at least the length specified by L1 and no longer than the maximum length specified by L2 are read (L3 is not used).
Interleaved 2 of 5 - Reading tolerance - Medium 444F01 Interleaved 2 of 5 - Reading tolerance - Low 444F02 Japan Post - 4-State postal barcode. - Only available with an area imager. Japan Post - Disable (*) 354000 Japan Post - Enable 354001 Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission.
Code mark - See "Data transmission settings - symbology identifier - Code mark" to activate or deactivate Code mark transmission. - Use the default value or compose your Code mark for this symbology (1 character). Japan Post - Symbology identifier - Code mark - * (*) 35482A Check digit transmission Japan Post - Check digit transmission - Enable (*) 355401 Japan Post - Check digit transmission - Disable 355400 Matrix 2 of 5 -Numerical symbology.
Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters). Matrix 2 of 5 - Symbology identifier - User defined - B4 (*) 45C000024234 Code mark - See "Data transmission settings - symbology identifier - Code mark" to activate or deactivate Code mark transmission.
Matrix 2 of 5 - Barcode length - Length mode - L1 as Minimal length (*) 455300 Matrix 2 of 5 - Barcode length - Length mode - L1, L2, L3 as fixed length 455301 Matrix 2 of 5 - Barcode length - Length mode - L1 as min, L2 as max 455302 Set length L1, L2 and L3 Set barcode length L1, L2 and L3 according to the barcode length mode used. MatrixCode - Two-dimensional alphanumerical symbology used by UPS. - Only available with models equipped with an area imager.
Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters). MaxiCode - Symbology identifier - User defined - D2 (*) 52C000024432 Code mark - See "Data transmission settings - symbology identifier - Code mark" to activate or deactivate Code mark transmission.
MaxiCode - Mode 0 - Enable 524101 Header MaxiCode - Mode 0 - Header - regular (AIM) (*) 524200 MaxiCode - Mode 0 - Header - Extended (Mode 2&3 like) 524201 MicroPDF417 - Two-dimensional symbology. - Alphanumeric full ASCII symbology - letter case defined. - It is highly recommended to select "stacked codes" in sensor optimization (see Operating settings/read optimization).
Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters).
MSI Code MSI Code - Disable (*) 464000 MSI Code - Enable 464001 Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters).
Check digit Check digit verification MSI Code - Check digit - Check digit verification - Modulo 10 (*) 464C01 MSI Code - Check digit - Check digit verification - Double Modulo 10 464C02 Check digit transmission MSI Code - Check digit - Check digit transmission - Enable (*) 465401 MSI Code - Check digit - Check digit transmission - Disable 465400 Barcode length Length mode MSI Code - Barcode length - Length mode - L1 as Minimal length (*) 465300 89
MSI Code - Barcode length - Length mode - L1, L2, L3 as fixed length 465301 MSI Code - Barcode length - Length mode - L1 as min, L2 as max 465302 Set length L1, L2 and L3 - Set barcode length L1, L2 and L3 according to the barcode length mode used. Multicode - The Multicode function is used configure the scanner to read a series of bar codes and then transmit them all at once. - Follow these steps to setup the Multicode function: 1. Activate the Multicode function. 2.
Multicode - Activation - Enable 594001 Multicode - Activation - Exclusive 594002 Bar code separator Compose up to 4 characters to be used as a separator between each bar code in the Multicode. Multicode - Bar code separator - "<>" (*) 59D200023C3E Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission.
Complete Multicode Compose Multicode - Symbology identifier - User defined - Incomplete Multicode default "UDM1" (*) 59D1000455444D31 Incomplete Multicode Compose Code mark - See "Data transmission settings - symbology identifier - Code mark" to activate or deactivate Code mark transmission. - Use the default value or compose your Code mark for this symbology (1 character).
Multicode - Incomplete transmission - Disable (*) 594200 Multicode - Incomplete transmission - Enable 594201 Incomplete transmission timeout - Select the timeout used when Incomplete transmission is active. The timeout starts after the last bar code is read. - Value is in milliseconds. Incomplete decode event - When active an Incomplete decode event is sent by the host if the trigger is deactivated until all codes in the Multicode are read.
PDF417 - Enable (*) 4C4001 PDF417 - Disable 4C4000 •Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters).
Structured append PDF417 - Structured append - Disable (*) 4C4100 PDF417 - Structured append - Enable 4C4101 Header transmission PDF417 - Structured append - Header transmission - Disable (*) 4C5800 PDF417 - Structured append - Header transmission - Enable 4C5801 Planet - Postal symbology . - Only available with models equipped with an area imager.
Planet - Enable 314001 Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters).
Planet - Check digit transmission - Disable 315400 Plessey Code Plessey Code - Disable (*) 474000 Plessey Code - Enable 474001 Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters).
Plessey Code - Symbology identifier - Code mark - D (*) 474844 Check digit transmission Plessey Code - Check digit transmission - Disable (*) 475400 Plessey Code - Check digit transmission - Enable 475401 Unconventional stop Plessey Code - Unconventional stop - Disable (*) 474300 Plessey Code - Unconventional stop - Enable 474301 98
Barcode length - Use the L1 as minimum length option if you know the minimum length of the codes in your application!!! - To optimize decoding performance and increase security, select the same length as the minimum length in your application (do not select a shorter length!!). Length = [start] + [barcode data] + [2-character Check digit] + [stop] - Minimum length possible = 5 characters. Maximum length possible = 25 characters.
Set length L1, L2 and L3 Postnet Postnet - Disable (*) 304000 Postnet - Enable 304001 Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters).
Postnet - Symbology identifier - Code mark - * (*) 30482A Check digit transmission Postnet - Check digit transmission - Enable (*) 305401 Postnet - Check digit transmission - Disable 305400 QR Code - Two-dimensional matrix symbology. - Only available with models equipped with an area imager. - Can encode up to 2509 numeric or 1520 alphanumeric characters. - Offers three levels of error detection. - Activating QR Code activates Model 2.
QR Code - Enable 554001 Model 1 control QR Code - Model 1 control - Disable (*) 554100 QR Code - Model 1 control - Enable 554101 Inverse video - Normal = used for decoding black bar codes printed on white background. - Inverse = used for decoding white bar codes printed on black background.
QR Code - Inverse video - Automatic 554202 MicroQR activation QR Code - MicroQR activation - disable (*) 554400 QR Code - MicroQR activation - enable 554401 Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters).
Code mark - See "Data transmission settings - symbology identifier - Code mark" to activate or deactivate Code mark transmission. - Use the default value or compose your Code mark for this symbology (1 character).
Standard 2 of 5 - Numerical symbology. - Default format = Identicon (6 start/stop bars). - Also referred to as "Straight 2 of 5" and "Industrial 2 of 5." Standard 2 of 5 - Disable (*) 484000 Standard 2 of 5 - Enable 484001 Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission.
Standard 2 of 5 - Symbology identifier - Code mark - D (*) 484844 Format Standard 2 of 5 - Format - Identicon (6 start/stop bars) (*) 485800 Standard 2 of 5 - Format - Computer Identics (4 start/stop bars) 485801 Check digit Check digit verification Standard 2 of 5 - Check digit - Check digit verification - Disable (*) 484C00 Standard 2 of 5 - Check digit - Check digit verification - Modulo 10 484C01 106
Check digit transmission Standard 2 of 5 - Check digit - Check digit transmission - Disable (*) 485400 Standard 2 of 5 - Check digit - Check digit transmission - Enable 485401 Barcode length - Use the L1 as minimum length option if you know the minimum length of the codes in your application!!! - To optimize decoding performance and increase security, select the same length as the minimum length in your application (do not select a shorter length!!).
Standard 2 of 5 - Barcode length - Length mode - L1 as Minimal length (*) 485300 Standard 2 of 5 - Barcode length - Length mode - L1, L2, L3 as fixed length 485301 Standard 2 of 5 - Barcode length - Length mode - L1 as min, L2 as max 485302 Sweden Post Sweden Post - Disable (*) 374000 Sweden Post - Enable 374001 Symbology identifier User defined - User defined symbology identifier.
- Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters). Sweden Post - Symbology identifier - User defined - P7 (*) 37C000025037 Code mark - See "Data transmission settings - symbology identifier - Code mark" to activate or deactivate Code mark transmission. - Use the default value or compose your Code mark for this symbology (1 character).
Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters). Telepen - Symbology identifier - User defined - C6 (*) 49C000024336 Code mark - See "Data transmission settings - symbology identifier - Code mark" to activate or deactivate Code mark transmission.
Barcode length - Use the L1 as minimum length option if you know the minimum length of the codes in your application!!! - To optimize decoding performance and increase security, select the same length as the minimum length in your application (do not select a shorter length!!). Length = [barcode data] - Minimum length possible = 1 character. Length mode - L1 = Codes with as many characters as specified by L1 and longer are read (L2 and L3 are not used).
TLC 39 - TCIF Linked Code 39. - Symbology consisting of two elements: MicroPDF417 code and a Code 39 code. - Available with firmware version 1.00 or higher. TLC 39 - Disable (*) 4E4000 TLC 39 - Enable 4E4001 Symbology identifier User defined - User defined symbology identifier. - See "Data transmission settings - symbology identifier - UDSI" to activate or deactivate UDSI transmission. - Use the default value or compose your custom symbology identifier for this symbology (1 - 4 characters).
TLC 39 - Symbology identifier - Code mark - * (*) 4E482A Linear transmission only TLC 39 - Linear transmission only - Disable (*) 4E4400 TLC 39 - Linear transmission only - Enable 4E4401 ECI security - Used to differentiate between TLC 39 and standard Code 39. - Higher security level = lower decode rate.
6. Operating Settings - Settings that affect the way your product operates (trigger settings, flashing mode, data decoding security settings, beep characteristics, etc.). Pre-defined trigger modes - These are pre-defined trigger settings used to quickly set up your scanner. - If you are using a pre-defined mode, do not set the other Scanning/triggering settings. One pull and release turns the aimer, illumination and decoding on.
Scanning / Triggering Triggering modes At power up the lighting and decoding are on all the time. The trigger is not used. Scanning / Triggering - Triggering modes - Continuous 704000 Lighting and decoding are on when the trigger line is activated (trigger pressed) and off when the trigger line is deactivated (trigger released).
At power up the lighting and decoding are on (no need to activate the trigger line) and after a period of inactivity lasting the time specified by the trigger timeout, the scanner starts flashing, checking for a bar code to be read. - When a bar code is detected, the lighting and decoding automatically turn on and stay on until another period of inactivity (timeout), after the timeout the scanner starts flashing again.
At power up lighting and decoding are on. - After a period of inactivity lasting the time specified by the trigger timeout, the lighting turns off or is dimmed (depending on the scanner used). - When a new bar code is presented the lighting and decoding restart and stay on until another period inactivity. - The trigger can be used in Presentation mode - when you pull the trigger the scanner functions as if it were in Level mode. - Only available with 2D models.
Scanning / Triggering - Trigger timeout (sec) - 2 (*) 70800002 Trigger activation - Used to enable or disable hardware or emulated triggers. - IMPORTANT: You cannot activate the trigger line if the hardware trigger is disabled. If you are using level or pulse trigger modes, the only way to re-activate the hardware trigger is by using online set up (ISCP terminal) or sending an ISCP command. Hardware and emulated triggers are disabled.
Scanning / Triggering - Trigger activation - Hardware and emulated trigger enabled (*) 704103 Software Trigger - Reading controlled by "start read" / "stop read" characters received from the host system. - This option is NOT compatible with ISCP. Scanning / Triggering - Software Trigger - Disable (*) 704200 - Start read character default = STX - Stop read character default = ETX - This option is NOT compatible with ISCP.
Compose start character Scanning / Triggering - Software Trigger - stop character [ETX] (03h) (*) 704403 Turn off after good read - When active, the scan engine stops the reading session after a successful decoding. - Turn off after good read is only used in the following trigger modes: - Level - Pulse - Autostand - Standard Aim - NOTE: this parameter is NOT used with continuous and flashing modes.
Scanning / Triggering - Turn off after good read - Retrigger delay - 0 (*) 70860000 Aimer mode - Allows you to locate the bar code you want to read. - The aiming beam is only used with the following trigger modes: - Level - Pulse - Autostand - Toggle* -NOTE*: In Toggle trigger mode, "one pull aim, one pull read" does not work as stated. Instead one pull turns on the aimer only. When the trigger is released decoding begins. If no decode, second pull turns aimer and decoding off.
Duration - Duration is applied differently depending on the aiming beam mode: - First pull aim and read: - Duration is the time the aiming beam stays on before reading begins - First pull aim, second pull read: - Duration is the maximum time between the first pull and second pull - If you wait longer than the duration before the second pull, the cycle starts over with the aiming beam.
Scanning / Triggering - Bad read message - Compose - NOREAD (*) 60C200064E4F52454144 Ignore stand detect Enable ignore stand detect when you want to use Autostand triggering mode with and you are not using a detectable stand (charge base or Bluetooth base station).
Scanning / Triggering - Double scan prevention - Enable 705001 Data decoding security - Ensures correct transmission of data for difficult reading conditions and varying levels of barcode quality (poorly printed labels, variable lengths and no check digit, "fragile" symbologies).
4 consecutive same reads before transmission. - 350 ms between identical consecutive codes. - 30 ms between different consecutive codes. Data decoding security - Predefined security levels - High 7140047180015E7181001E Consecutive same read data validation - Data is only transmitted after repeated reads give the same result.
Center decoding - When enabled the scanner reads only the bar code that the laser aimer is aimed at. - This is helpful when reading bar codes that are positioned close together. Activation Data decoding security - Center decoding - Activation - Disable (*) 714100 Data decoding security - Center decoding - Activation - Enable 714101 Tolerance - The tolerance level for center decoding allows you to aim the laser close to the bar code to be read rather than be positioned on the bar code.
Bar code sequence - Bar code sequence allows you to read up to 10 bar codes with one trigger pull. This is useful when reading several bar codes placed closely together and without re-reading the same code twice. - For example, if set to 2, pull the trigger once and scan both codes. The scanner beeps for each code that is decoded (2). If "turn off after good read" is enabled the scanner turns off AFTER the last bar code in the sequence is read. - Compose the number of bar codes for the sequence.
Power-up beeps 2 beeps = successful power-up 3 long beeps = EEPROM integrity error (contact your Intermec representative !). Beeps / LEDs - Power-up beeps - Disable (*) 724000 Beeps / LEDs - Power-up beeps - Enable 724001 Good read beeps Number - "Normal" bar codes: 1 beep (default) = good read - Configuration codes: 2 beeps = good read, 6 beeps = setup error, 3 long beeps = EEPROM integrity error (contact your Intermec representative !).
Beeps / LEDs - Good read beeps - Number - None 724100 Duration - Value is in milliseconds Beeps / LEDs - Good read beeps - Duration - 60 7281003C Beeps / LEDs - Good read beeps - Duration - 80 (*) 72810050 Beeps / LEDs - Good read beeps - Duration - 200 728100C8 Beeps / LEDs - Good read beeps - Duration - 300 7281012C 16
Timing - IBM and OCIA cash registers: do not send this parameter online to the scan engine through RS-232 cable 0-364032-10!!! Send it to the setup sheet and read the configuration code with your normal IBM / OCIA product cable connected.
Beeps / LEDs - Good read LED duration - 500 728201F4 Beeps / LEDs - Good read LED duration - 1000 728203E8 Beeps / LEDs - Good read LED duration - 2500 728209C4 Beeps / LEDs - Good read LED duration - 5000 72821388 Disable/enable all good read signals - This setting can be used to disable all good read signals: Beep, LED and vibrate.
Beeps / LEDs - Disable/enable all good read signals - Enable (*) 725101 Error beep Beeps / LEDs - Error beep - Enable (*) 724301 Beeps / LEDs - Error beep - Disable 724300 Setup beep and LED Beeps / LEDs - Setup beep and LED - Enable (*) 724401 Beeps / LEDs - Setup beep and LED - Disable 724400 19
Multicode beeps - By default the scanner does not beep when reading several bar codes when using the Multicode function (see Symbologies). Use this setting to activate beeps when reading bar codes that are part of a Multicode.
7. Configuration Modes And Utilities Get version info. Get firmware version 30C0 Get decode version info. Get decode version 30C2 Get all component versions.
Necessary for upgrade of product firmware. - Use the Intermec Firmware Download Wizard to upgrade your product (available from the cd-rom or web, can be run from EasySet "Tools" menu if installed in "download" subdirectory in EasySet directory). - Reading this code prepares the product for firmware upgrade but inhibits normal operation (restart the product to resume normal operation).
Protects the product against unwanted configuration by bar code. - Configuration with bar codes only possible before end of 1 minute timeout (cycle repeated until no config code read within 1 minute). Optical setup (using configuration bar codes) - Inhibit after 1 mn 744001 Transparent configuration mode - Allows you to use your scanner to set up other products (setup commands are transmitted to the other product but do not affect your scanner).
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digi tal device, pursuant to part 15 of the FCC rules.