User's Manual

4.3.9 Buzzer (in Scanner and Cradle): 90dB from 10cm distance
measured
4.4 Communications
Cradle / Host: Keyboard Wedge / RS232 / USB for IBM PC or
compatible, MAC,
and common terminals. (replace the interface cable on
cradle without changing H/W or F/W)
4.4.1
4.4.2
4.4.3
4.4.4
4.4.5
4.4.6
Radio: unlicensed 2.4GHz point to point
Transmit Power (dBm): 0 dbm
Radio Range: under 30M, line of sight
Out of Range detection: error tone indication and scanner doesn’t
transmit the code decoding
Cable fall off detection
4.5 Programming Method
4.5.1 User’s Manual: Reading special bar codes. Set up cloning would also
be considered
4.5.2 Scanner Configuration Manager (SCM)
4.5.3 Special Features: Programmable data format (code identification,
preambles and postambles, intercharacter and intermessage delays, variable
time-out
, and data editing)
4.6 Environmental
4.6.1 Temperature Operating: 0 ~ 50, Storage: -20 ~ 70
4.6.2 Humidity: 5% – 95%, no condensing
4.6.3 ESD Protection: Meet ESD 8K contact and 12K Air
4.6.4 Electrical Safety: Complies with FCC Class A, CE, DGT and BSMI
regulations (label format should meet an integrated consideration)
4.6.5 Laser Safety: CDRH Laser Class 2
4.7 Cradle and Accessories
4.7.1 Cradle and 9V / 2A Power adaptor Unit