7.3  Programming the Output Relays 
It is possible for each of the 5 backup customer codes to activate a different relay 
(or set of relays). After the change-relays password has been entered, the 
interface will beep once and wait for you to define which relay(s) should be 
activated when the first backup customer code is entered (see table on the next 
page). After you press the keys that define which relays will activate (press only 
one key at a time), press the 0 key to finalize your selections. The interface 
board will beep twice to indicate that it is waiting for you to define the relays 
associated with the second backup customer code. Repeat the process for all 5 
backup customer codes. 
Key OUTPUT RELAY 
1 
1 
2 
2 
3 
3 
4 
4 
5 
5 
6 
6 
7 
1 pulse on Relay 1 
8 
2 pulses on Relay 
1 
9 
3 pulses on relay 1
Example to define relays as follows: 
 Code #
  Relays 
 1  1 
  2    1 + 4 
 3  2 
  4    2 + 4 + 5 
  5    2 pulses on 1 + 3 